EasyManua.ls Logo

Instanta Limited ucd series User Manual

Default Icon
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
INSTANTA LIMITED
S E R V I C E M A N U A L
ISSUE: 1- Dated: October 2009
“UCD” SERIES
AUTOMATIC FILL, UNDER-COUNTER HOT WATER DISPENSERS
CONTENTS
Section: Page No:
Contents p.1
Introduction p.2
Principle of Operation p.2
1 .0 Technical Specifications p.3
2.0 Installation Checklists p.4
3.0 The LCD Display p.5
4.0 Temperature Adjustment p.6
5.0 Water Dispense settings & adjustment p.6
6.0 Sensing Probes p.7 - 8
7.0 Thermistor p.7
8.0 Heating Elements p.8
9.0 Triac p.9
10.0 Printed Circuit Boards p.9 - 11
11.0 Transformer p.12
12.0 Hot Water Pump p.12
13.0 Hot Water Gate-Valve & Recirculation p.12 - 13
14.0 Thermal Cut-outs p.13
15.0 Solenoid Valve p.14
16.0 Hot Water Dispense Font p.14 - 15
17.0 Storage Tank p.15
18.0 De-scaling p.15 - 16
19.0 Fault-Finding p.17 - 18
20.0 Warning Messages p.19 - 20
21.0 Exploded Drawings & key p.21 - 24
22.0 Wiring Diagrams p.25 - 26
Question and Answer IconNeed help?

Do you have a question about the Instanta Limited ucd series and is the answer not in the manual?

Instanta Limited ucd series Specifications

General IconGeneral
BrandInstanta Limited
Modelucd series
CategoryDispenser
LanguageEnglish

Summary

Introduction

Principle of Operation

Explains how the UCD dispenser operates, including heating and dispensing cycles.

Technical Specifications

Installation Checklist

LCD Display and Programming

Temperature Adjustment

Water Dispense Volume Adjustment

Explains how to configure measured volume or on-demand dispensing for the UCD series.

Sensing Probes

Heating Elements and Boil-Dry Protection

Triac and Printed Circuit Boards

PCB Diagnostics and Warnings

Critical Warnings and Other PCBs

Transformer and Hot Water Pump

Thermal Cut-Outs

Over-Boil and Boil-Dry Protection

Explains the function and reset procedure for over-boil and boil-dry thermal cut-outs.

Solenoid Valve and Dispense Font

De-scaling Instructions

Fault Finding

Machine Symptoms and Causes

Lists symptoms like 'Dead', 'Overfilling', 'Not Filling' with their causes.

Fault Finding: Additional Symptoms

Service Warning Messages

Critical Warning Messages