ENGLISH
Quick Installation Guide
MRX LTE
www.insys-icom.com
These short operating instructions apply for the following devices of INSYS icom:
MRX3 LTE
MRX5 LTE
www.insys-icom.com/manual
It is intended for a quick commissioning by the operator. Refer to the associated manual for further information.
This and other associated manuals can be found on our website in the menu Support and Downloads >
Documentation. Scan the QR code above or enter the URL into your web browser.
Defects liability terms
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently qualified
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. The liability of the
manufacturer ceases to exist.
Intended Use
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used for the
following purposes:
Usage and mounting in an industrial cabinet.
Switching and data transmission functions in machines according to the machine directive 2006/42/EC.
Usage as data transmission device, e.g. for a PLC.
The product may not be used for the following purposes and used or operated under the following conditions:
Use, control, switching and data transmission in machines or systems in explosive atmospheres.
Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a
breakdown occurs.
Technical Boundaries
Max. line length for antennas, power supplies, serial interfaces, inputs and outputs as well as other signals: 30 m
Max. line length of USB connection lines: 3 m
Cable cross-section: 0.25 … 1.5 (2.5) mm² (depending on terminal size), flexible lines require end sleeves
Support
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail
under support@insys-tec.de.
Technical Data
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits must be observed.
Operating voltage (redundant)
12 V … 24 V DC (±20%)
GSM/GPRS frequencies (2G)
Power consumption
typ. 2.5 W, max. 8 W
fully equipped: max. 20 W
UMTS/HSPA frequencies (3G)
Level input IN1
HIGH level = 2 ... 24 V
LOW level = 0 ... 1 V
Contact open condition: HIGH
LTE frequencies (4G)
Current consumption input IN1
at LOW potential
typ. 0.1 mA when connecting
to GND
Real-time clock (RTC) buffer
time
Level input IN2
HIGH level = 10 ... 24 V
LOW level = 0 ... 5 V
Contact open condition: LOW
Temperature range
Power consumption input IN2
at HIGH potential
max. 3 mA at 24 V DC
Maximum permissible humidity
IP rating