INTELLITEC
PDX RV LLC
than 10.5 Volts DC for the latching relay to close or
open. If batteries are below 10.5 Volts DC, charge
batteries and retest. If the batteries are charged and
are above 10.5 Volts DC go to step 48.
Trouble Shooting
Problem
engage (latch), BD2
& BD3 MODELS
With an assistant, press and hold momentary
switch, at the same time check for voltage across
the coil terminals of the chassis battery relay(+ on
the "I" terminal and ground on the "S" terminal), If
0 volts go to step 49. If voltage is 10.5 VDC or
larger between the “I” & “S” terminals, replace
chassis relay.
Remove battery disconnect panel from cabinet /
console and with a multi-meter set on DC voltage,
measure between the orange wire at pin # 7 and the
black wire on pin # 12. The voltage should read
the same approximate value as the batteries. If not
replace harness, refer to PARTS LINK#1 (page 7).
If the voltage reading is the same go to step 50.
meter set on DC voltage, measure
between the orange wire at pin # 7 and the gray
wire on pin # 8 while the switch is depressed. The
voltage should read the same approximate value as
the batteries. If not replace disconnect panel, refer
to PARTS LINK # 2 (page8). If the reading is the
same go to step 51.
between the black wire at pin # 12 and the violet
wire on pin # 6 while the switch is pressed. The
voltage should read the same approximate value as
the batteries. If not replace disconnect panel, refer
to PARTS LINK # 2 (page 8).
16