53‐01118‐100RevB06/09/2020
Page1
USER’SGUIDE
BatteryGuard
®
1000(12v)
Partnumber:00‐01118‐000
TheBatteryGuard®1000providesasolutionforprotectingyourbatteriesfromdischargingtoalevelthatmight
damageyourbatteriesortoalevelthatpreventsthevehiclefrombeingstarted.TheBatteryGuard®1000
constantlymonitorsthevoltagelevelofthebatterytodeterminethelevelofcharge.Whenthevoltagedrops
belowthelowvoltagethresholdforaspecifieddurationoftime,theBatteryGuard®1000willautomatically
disconnectthebatteryfromthesystemload,protectingthebatteryfromexcessivedischarge.
IftheBatteryGuard1000®sensesachargingpotentialforaspecifieddurationoftime,thenitwillautomatically
reconnectthesystemload.Thisconditionusuallyoccurswhenachargingdeviceisconnectedtothebatteryor
theengineisrunning.
ConnectingandDisconnectingtheSystemLoads
TheBatteryGuard®1000acceptsamomentaryswitchinputsignal.Thisswitchallowsusercontroltomanual
disconnectorreconnectthesystemloadsattheuser’sdiscretion.Simplypushandreleasethepushbuttonand
theBatteryGuard®1000willswitchstates.Keepinmind,thedevicehasabuilt‐instatechangedelayof5
secondstopreventconstantcyclingofthedisconnect.
Note:Iftheuserchoosestodisconnectthesystemmanually,theBatteryGuard®1000willnotautomaticallyreconnectifit
sensescharging.
Alarmindication
Analarmoutputisusedtoprovidetheuserwithvaluableinformationaboutthestateofthedisconnect.Thisisa
highsideoutputalarmthatislimitedto300mA.WhenusedwithIntellitec’sBatteryGuardSwitch(11‐01085‐
001),thisoutputistiedtoanLEDindicator.
SolidOn–Indicatesthatthesystemloadsareconnected,andthebatteryvoltageisabovethelowvoltage
threshold.
Flashingat½Hz–Indicatesthatthesystemloadsareconnected,andthebatteryvoltageisbelowthelow
voltagethreshold.
SolidOff–Indicatesthatthesystemloadsaredisconnected.

Other manuals for Intellitec Battery Guard 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intellitec Battery Guard 1000 and is the answer not in the manual?

Intellitec Battery Guard 1000 Specifications

General IconGeneral
BrandIntellitec
ModelBattery Guard 1000
CategoryControl Unit
LanguageEnglish

Related product manuals