Intercall 600/700 Installation & Operation Guide Issue 4.27 Page 60 of 78
L758 Standard Display Menu Settings (not L628, L748 or L762)
Access to the display menus is obtained by first pressing and holding down the ‘Show Staff’ button. While holding
down the ‘Show Staff’ button, press and hold the ‘Accept Call’ button. After holding both buttons down for 10
seconds, you should gain access to the menus. To change the displayed option, press the ‘Show Staff’ button. To move
to the next item, press the ‘Accept Call’ button. When the display is showing the last menu item (EMERGENCY
CALLS), one more press of the ‘Accept Call’ will return the unit to normal operating mode. Please note while in the
menu mode, the unit will not respond to system activity. You will need to fit the menu enable jumper to gain access to
the L628 Display Menus.
Menu Settings Description
DISPLAY ADDRESS:
00
00 to 07*
Sets the Display Address of the unit. When display address 1 or
above is selected, and the unit is not in master mode, the menu
will jump to 2ND TONE LO ADD. *Earlier software revision
has a range of 00 to 15, do not use above 07.
ZONE A LOW ADD:
001
001 to 215
Select the Lowest call point address for zone switch position A.
This function is available only when the display is in master
mode or set to Display Address 00.
ZONE A HI ADD:
215
001 to 215
Select the Highest call point address for zone switch position A.
This function is available only when the display is in master
mode or set to Display Address 00.
ZONE B LOW ADD:
001
001 to 215
Select the Lowest call point address for zone switch position B.
This function is available only when the display is in master
mode or set to Display Address 00.
ZONE B HI ADD:
215
001 to 215
Select the Highest call point address for zone switch position B.
This function is available only when the display is in master
mode or set to Display Address 00.
ZONE C LOW ADD:
001
001 to 215
Select the Lowest call point address for zone switch position C.
This function is available only when the display is in master
mode or set to Display Address 00.
ZONE C HI ADD:
215
001 to 215
Select the Highest call point address for zone switch position C.
This function is available only when the display is in master
mode or set to Display Address 00.
2ND TONE LOW ADD:
OFF
OFF / 001 to 215
Select the Lowest call point address for the Second Tone alarm
setting. This range operates in addition to the zone windows
above.
2ND TONE LOW ADD:
OFF
OFF / 001 to 215
Select the Highest call point address for the Second Tone alarm
setting. This range operates in addition to the zone windows
above.
ACCEPT BUTTON:
ENABLED
ENABLED
DISABLED
When enabled, allows the calls to be accepted at this display
using the Accept button. When disabled, this function does not
operate on this display only.
SHOW ALL CALLS:
ENABLED
ENABLED
DISABLED
When enabled, this display will show all calls on the system but
will only sound the audible alarm for calls in the current zone.
SOUND FOR:
ALL CALLS
ALL CALLS
EMERGENCY CALLS ONLY
Select “Emergency Only” to allow Emergency and Attack calls
only to generate the audible alarm from this display. All other
call types will be shown but the audible alarm will not operate
on this display.
EMERGENCY CALLS:
ALL ZONES
OWN ZONE ONLY
ALL ZONES
Select “All Zones” to allow this display to show and sound for
Emergency and Attack calls in all zones on the system. “Own
Zone Only” will not show or sound for Emergencies or Attack
calls on other zones.

Table of Contents