Intercall 600/700 Installation & Operation Guide Issue 4.27 Page 61 of 78
L762 Call/Display Menu Settings
The L762 Call/Display has a unique menu structure, based on the standard display menu, but with additional functions
relating specifically to this unit. Access to the menus is obtained by; pressing and holding down the ‘Reset’ button.
While holding down the ‘Reset’ button, press and hold the ‘Talk’ button. After holding both buttons down for 10
seconds, you should gain access to the menus. To change the displayed option, press the Reset’ button. To move to the
next item, press the ‘Talk’ button. When the display is showing the last menu item (DEFAULT TEXT), one more press
of the ‘Accept Call’ will return the unit to normal operating mode. Please note while in the menu mode, the unit will not
respond to system activity. This unit can only be configured as a slave display and must receive the zoning information
from a master display set to the same display address.
Menu Settings Description
DISPLAY ADD: 00
00 to 07
Sets the Display Address of the unit. When display address 1 or
above is selected, the menu will jump to 2ND TONE LO ADD.
This Unit can only be configured as a slave display and must
receive the zoning information from a master display set to
the same display address.
ZONE A LO: 001
001 to 215
Select the Lowest call point address for zone switch position A.
This function is available only when the display is set to Display
Address 00.
ZONE A HI: 215
001 to 215
Select the Highest call point address for zone switch position A.
This function is available only when the display is set to Display
Address 00.
ZONE B LO: 001
001 to 215
Select the Lowest call point address for zone switch position B.
This function is available only when the display is set to Display
Address 00.
ZONE B HI: 215
001 to 215
Select the Highest call point address for zone switch position B.
This function is available only when the display is set to Display
Address 00.
ZONE C LO: 001
001 to 215
Select the Lowest call point address for zone switch position C.
This function is available only when the display is set to Display
Address 00.
ZONE C HI: 215
001 to 215
Select the Highest call point address for zone switch position C.
This function is available only when the display is set to Display
Address 00.
2ND TONE LO: OFF
OFF / 001 to 215
Select the Lowest call point address for the Second Tone alarm
setting. This range operates in addition to the zone windows
above.
2ND TONE HI: OFF
OFF / 001 to 215
Select the Highest call point address for the Second Tone alarm
setting. This range operates in addition to the zone windows
above.
DISPLAY MODE:
NURSE PRES ONLY
NORMAL DISPLAY
SILENT DISPLAY
Select when the LCD display is enabled. NURSE PRES ONLY
will enable the display only when the unit is in Nurse Present
Mode. NORMAL DISPLAY will enable the display & audible
alarm continuously. SILENT DISPLAY will enable the LCD
continuously, however the audible alarm will only operate when
the call point is in Nurse Present mode.
SHOW ALL CALLS:
ALL ZONES
OWN ZONE ONLY
Select “All” to allow this display to show and sound for
Emergency and Attack calls in all zones on the system. “Own
Zone Only” will not show or sound for Emergencies or Attack
calls on other zones.
SOUND FOR:
ALL CALLS
EMERGENCY ONLY
Select “All” to allow this display to respond for all call levels,
Select “Emergency Only” to ignore all calls apart from
Emergency and Attack Calls.
EMERGENCY CALLS:
ALL ZONES
OWN ZONE ONLY
Select “ON” to show the top line of the default text in quiescent
mode eg “INTERCALL”. Select “OFF” to clear the display in
quiescent mode. A single red led will continue to flash indicating