SERIAL PAGER DESPATCH ENTRY AND MESSAGE MANIPULATION
Below, we show the Serial Pager Despatch Entry in greater detail.
The Choice of Field types which can be sent to pager:
Channel Name – The Channel name of this PSU as entered into the communications page Eg “BLOCK 5”
Address Name – The Address description of the calling device – Eg “BEDROOM 34”
User Name – The User ID description of the calling device – Eg “USER ID 001”
Event Name – The Event name of the calling device “Eg CALL”
Hour ASCII – The on board clock Hour count as a printable number.
Minute ASCII – The on board clock Minute count as a printable number.
Second ASCII – The on board clock Hour count as a printable number..
Day ASCII – The on board clock Day as a printable number.
Month ASCII – The on board clock Month as a printable number.
Year YY ASCII – The on board clock Year as a two digit printable number.
Year YYYY ASCII – The on board clock Year as a four digit printable number.
Driver Field – Enter the Field Data as 1,2,3 or 4 which picks the string entered into the Driver Field 1,2,3,4.
Custom Char – Enter the Field Data as the ASCII representation of the character
Commonly Used ASCII Characters: 32 is a space, 13 is carriage return, 10 is line feed, 11 is form feed refer to
http://en.wikipedia.org/wiki/Ascii for more information.
Please note, the use of Field Types not listed above in a message may result in spurious pager behaviour
and/or spurious characters on the pagers. Custom Characters below 32 or above 127 should not be used.