A blank reading on a spa Control Panel indicates components such as RCD failure, PCB failure or a
connection issue between the Panel & Base.
1. Test the socket voltage, is the voltage is close to wall output?
2. Reconnect Signal Line, reference to Page 12 (Opening the Control Base) for signal connection.
3. Replace a control panel, and power on the system again.
4. If blank panel still persists, replace a new PCB or RCD, refer to the section replacing the PCB or
RCD for more details.
1. Replace PCB, or
2. Replace RCD, or
3. Replace Power Cord
Replace a control panel, run system
END
Plug in and Reset RCD
Reconnect Signal Line
Panel Blank?
Panel Blank?
No
Yes
No
Yes