Wood stove REMILLY Référence: P601384
Code 1
XD, le 22/06/2021 Page 11 of 18
Specific user and installation manual
Please read this additional specific manual and the general manual also provided with the appliance carefully
Specifications as per EN 13240:
Construction specifications:
Flamme Verte classification
Released dust concentration at 13% of O2
Wood / 25 cm logs
maximum possible length (horizontally): 34 cm
Floor protection
The appliance must not be placed directly on flooring made of combustible materials or that could be damaged by heat.
If this occurs, place the appliance on a 50 cm wide and 50 cm long concrete slab, 45mm thick, covered with a reflective
surface on the appliance side (stainless steel type plate or plate with a glossy ceramic surface), the appliance should be
in the middle of this slab.
Minimum distance from adjacent combustible materials: 60 cm
If the neighbouring walls are made from non-combustible materials that are not damaged by heat (the wall temperature
can reach 200°C), these distances can be reduced to 15 cm.
Connection to the chimney flue using the nozzle
on the top of the appliance
Engraved on the underside of the ash pan