WARNINGS
Before installing the unit, agree with the customer the site.
WARNINGS
Pay scrupulous respect to safety distances between the unit and
other equipment or structures to ensure that air entering the unit
and discharged by the fans is free to circulate.
WARNINGS
The unit must be installed in a space designed to house technical
installations dimensioned according to legislation in force in the
country concerned and large enough to allow access for
maintenance.
DANGER
This photovoltaic micro-inverter is only for use in a
closed electrical operating area! The device shall not
be energized during installation or maintenance!
An internal isolation transformer is provided in micro-inverter, internal transformer
is galvanic isolation from the MAINS and PV array by reinforced insulation. PV input
circuit is earthed, and non-earthed pole of PV input keeps basic insulation isolation
from earthed metal.
In accordance to EN 62109-1:2010, circuits complying with the requirements for
DVC-A are considered safe to touch, however, since the device is intended for
outdoor use and Vmax PV is rated 50V D.C, which exceeds maximum 35V DC limit for
DVC-A in WET LOCATION as below: