EasyManua.ls Logo

INVT iMars BG25KTR

INVT iMars BG25KTR
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iMars grid-tied solar inverters Operation
37
Figure 5.1 Remove the cooling chamber
Figure 5.2 Remove the fan mounting plate
(5) Use soft brush or vacuum cleaner to clean the cooling chamber and the fans.
(6) Assembly the cooling chamber or fan mounting plate into inverter.
(7) Re-install the inverter to its original position as Section 4 of the content.
(8) Repeat Section 5.1 operating content.
(9) Restart the inverter.
Fan Replacement
If the inverter reports over-temperature fault, or non-normal fan operation noise, please
replace the fan. This operation must be carried out by professionals.
z Inverter should be shut down before maintenance work begins, and
disconnect all power inputs.
z
Wait at least 10 minutes, until the inverter internal capacitors discharge before
maintenance work.
z Fan replacement must be carried out by professionals.
Fan replacement procedure is as follows:
(1) Disconnect the input and output switches.
(2) Make DC switch to the "OFF" position.
(3) Wait ten minutes.
(4) Remove the inverter as the reverse steps of Section 4 content.

Other manuals for INVT iMars BG25KTR

Related product manuals