2.2.2 Inxpect SRE 200 Series
The maximum length allowed of the whole CAN bus line (from termination to termination) is 100 metres,
regardless of the conductor section of the CAN bus cable.
A maximum number of two bus lines is allowed. Then, the sum of the length of the two lines must be lower (or
equal to) 100 metres.
Please use the Inxpect SRE 200 Series Cable Validator tool to check and validate your desired cable
configuration.
The tools is going to request the following parameters:
- number of BUS lines (one/two)
- number of sensor for each line (up to six)
- length of each cable*
- Power Supply cable section**
* See sections 3.1.2 and 4.1.2 to know the standard lengths provided by Inxpect
** Standard cables provided by Inxpect have a power supply section of 0.50 mm² (AWG21)
2.2.2.1 Examples (Inxpect SRE 200 Series)
● Example 1 - Multiple sensors on the same bus line (chain of sensors), a valid configuration
In the following example we have:
- number of BUS lines: 1
- number of sensor for each line: 3
- length of each cable: 10+5+10 [m]
- Power Supply cable section: 0.50 mm²