iO
T
i
tan Touchscreen Thermostat





I
u,ao �!


Fan
�

  





User Manual
L

Other manuals for iO HVAC Controls Titan UT32

Questions and Answers

  • T
    Timothy PughAug 10, 2025
    Why is my iO HVAC Controls Thermostat temperature display inaccurate?
    • B
      bobby27Aug 10, 2025
      If your iO HVAC Controls Thermostat's temperature display is inaccurate, it might be due to air leaking from the wall cavity into the thermostat's rear. To fix this, seal the hole where the wiring enters the subbase to prevent air infiltration. Also, external factors like lamps or drafts can affect the accuracy. Ensure to move any heat sources away from the thermostat.
  • S
    swardAug 15, 2025
    What to do if the iO HVAC Controls Thermostat fan keeps running?
    • J
      James WeeksAug 15, 2025
      If the fan in your iO HVAC Controls Thermostat continues to run after heating or cooling is complete, the fan mode might be set to 'Always On'. Touch the fan icon and change the setting to 'Automatic'. Alternatively, if your thermostat is programmable, the fan operation could be programmed for 'Automatic' or 'Siempre On' with each event. If you don't need the Programmable Fan feature, set Option 04 = 1.
  • J
    Jodi NelsonAug 21, 2025
    How to unlock iO HVAC Controls Thermostat settings?
    • L
      Louis PenningtonAug 21, 2025
      If some functions on your iO HVAC Controls Thermostat cannot be changed and there is a padlock displayed, it means lock values have been set. To remove these, go to Installer Option menu 06 and set it to 0.
  • J
    jesse43Aug 25, 2025
    How to set iO HVAC Controls Thermostat to auto changeover?
    • J
      John GilesAug 26, 2025
      If your iO HVAC Controls Thermostat cannot be set for auto changeover, Installer Option 03 needs adjustment. Set it to 0 for Heat/Auto/Cool/Off operation, or Heat/Auto/Cool/Emergency Heat/Off for heat pumps. Note: 03 = 1 is for Manual Changeover (Heat/Cool/Off), 03 = 2 for Heat Only (Heat/Off), and 03 = 3 for Cool Only (Cool/Off).
  • C
    colleen02Aug 31, 2025
    How to fix iO HVAC Controls Thermostat with no LCD display?
    • M
      melendezkeithAug 31, 2025
      If your iO HVAC Controls Thermostat has no LCD display, and it's battery powered, remove the battery compartment. Check that the positive (+) and negative (-) ends of each battery are correctly oriented. Also, ensure the thermostat is securely attached to the subbase with no exposed gaps.
  • J
    Jeremy ThomasSep 4, 2025
    What to do if iO HVAC Controls Thermostat not displaying outdoor temperature?
    • S
      Steven AlvarezSep 4, 2025
      To address this issue with your iO HVAC Controls Thermostat, check the wiring at the outdoor sensor and the sensor terminals on the subbase. Ensure that the outdoor sensor wires are connected to terminals S2 and SC.

iO HVAC Controls Titan UT32 Specifications

General IconGeneral
Input Voltage20-30 VAC 50/60 Hz
Relay Rating24 VAC @ 1 Amp maximum per relay
Battery Power2 AA 1.5 V
Operating Temperature32° F to 150° F
Operating Relative Humidity0-95% RH (non-condensing)
Storage Temperature32° F to 150° F
Back LightBlue LED
Displayed Temperature Resolution1° F
Short-cycle Delay4 minutes
Setpoint Range Heating41° F - 120° F
Setpoint Range Cooling43° F - 122° F
Onboard and Remote SensorsNTC type 2
Resistance10KΩ @ 77 F°
Tolerance+ / - 3% @ 77 F°
Weight and Dimensions IconWeight and Dimensions
Overall Size5.5” W x 3.75” H x 1.312” D
LCD Display Size4.125” W x 2.375” H