EasyManua.ls Logo

Ioline FlexJet E Install Ribbon Cable 3C Fje

Ioline FlexJet E
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
14140 NE 200th St.
Woodinville, WA 98072
1.425.398.8282
www.ioline.com
Install Ribbon Cable 3C FJE
Kit for # 109519, Procedure P/N 110623 Rev 0
Step 1: Wire cutters, Phillips screw driver, 9/64” hex
driver, 6 nylon zip ties and a grounding wrist strap.
Step 2: The ribbon cable. Should come with the 6
nylon cable zip ties to attach to the carriage.
Step 5: Remove the rear cover (18) screws. Place to
the side.
Step 4: After removing the left cover, using the hex
driver, loosen the belt by turning the screw (arrow) 2
turns counter clockwise.
Step 6: Remove the carriage cover (4) screws.
Step 7: Unclip the Y belt from the carriage. Remove
the carriage from the traverse by pressing down on
the threaded screw (arrow), then pull forward.
Step 8: You need to start to remove the old ribbon
cable. With the wire cutters, snip all the white cable
ties. There should 5. Cut and remove them.
Step 3: Turn off, unplug the power cord and the com-
munication cable. Remove the right cover.
Tools Required: