EasyManua.ls Logo

IPC IWD-H Series - Page 25

IPC IWD-H Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
- 25 -
FIG. 9
FIG.11
STOPPING THE CLEANER
1) Switch o󰀨 the burner by
turning the pressure regulator
to pos. "0" (g. 7B).
2) Let the cleaner run with
cold water only for at least
30 seconds to cool down the
boiler.
3) After using with detergent,
ush out the intake circuit;
place the detergent suction
hose (g. 9) in a tank of clean
water and let the pump run for
1 minute with the dosing tap
turned fully on.
Repeat the operation with
the detergent selector set
rst to position 1 and then to
position 2.
4) Stop the cleaner by turning
the selector switch to pos. "0"
(g. 7A).
5) Discharge the pressure
from the H.P. hose by pressing
the trigger on the gun (g. 6).
6) Disconnect the water clea-
ner from the mains electricity
supply via the omnipolar
switch or by unplugging the
plug from the socket.
7) Turn o󰀨 the water supply
tap (g. 5A).
USE OF THE DOUBLE LAN-
CE (g. 10)
The double lance allows the
operator to select a low or high
pressure jet. The pressure is
selected with the gun in pos.
1. High pressure: pos. 2. Low
pressure pos. 3.
Warning
- If the water cleaner is left,
even temporarily, turn it o󰀨 by
using the omnipolar switch or
by unplugging the plug from
the socket.
- Water cleaners with the
“Total Stop” device should
be considered as o󰀨 when
the omnipolar switch is in
the “O” position or the plug
is unplugged from the sock-
et.
- When the water cleaner is not
used, close the safety device
on the handle.(g.11)
- Dry use of the water cleaner
FIG. 10
!
causes serious damage to
pump gaskets.
FIG.12
USING STEAM
Use the steam nozzle (sup-
plied as an accessory).
Turn the thermostat knob
“B” (g. 7) to steam position
to obtain an increase in the
temperature of the water at
delivery (140°C - 284°F).
Turn the steam tap anti-clock-
wise to open the steam.
At work temperatures higher
than 95°C (203°F), the work
pressure must be < 32 bar
(460 PSI).
Danger
During use with boiling water, "Steam Phase", keep away
from the openings for fumes discharge (risk of burning).
When you have nished using the "Steam Phase", turn
the thermostat knob "B" to position "0" (g. 7) and let
the machine cool down for about 3 minutes with the gun
turned on.
!
Turn the steam tap clockwise again to shut o󰀨 the steam.