5
IMPORTANT INSTRUCTIONS
IMPORTANT INSTRUCTIONSIMPORTANT INSTRUCTIONS
IMPORTANT INSTRUCTIONS
Before use, the equipment must be correctly assembled with all of its components
Check that the electrical outlet is correct for use with the plug on the machine
Before connecting, check that the specified motor voltage corresponds to the main
voltage available
Never use the equipment near flammable, explosive or toxic substances: sparks from
the motor could cause dangerous reactions.
Always unplug the machine from the electrical outlet when leaving machine unattend-
ed or before attempting any repair.
Service and repair should be done by qualified personnel only. Use only original
manufacturer’s replacement parts.
Operation
OperationOperation
Operation
This machine is a commercial vacuum designed for wet pick up. And must be stored in a
This machine is a commercial vacuum designed for wet pick up. And must be stored in a This machine is a commercial vacuum designed for wet pick up. And must be stored in a
This machine is a commercial vacuum designed for wet pick up. And must be stored in a
dry location.
dry location.dry location.
dry location.
Machines with dual vacuum motors can be run together or independently as the job
requires.
This machine is equipped with a sump pump that has it’s own independent switch.
When the water level rises, the pump will turn itself on and pump the water out
through a connected discharge hose.
The machine is also equipped with a shut-off float. As the tank is filled to capacity, a
float rises and seals the vac intake, causing a loss of vacuum. Switch off the vacuum
when this happens and bring the machine to a drain.
To empty the machine, make sure the power cord for the sump pump is plugged into
the A.C. receptacle on the vacuum power head or into a separate wall outlet.
After Use
After UseAfter Use
After Use
1
.
Store the cord on the hook.
2. Store the appliance indoors, away from sources of heat.
3. This appliance is provided with an automatically reset
thermal limiter to avoid damage to motor. If thermal limiter
operates do one or more of the following:
Change the bag
Clean or replace the cartridge filter
Check hose and tank inlet for any obstructions
Wait a few minutes for the thermal limiter to re-close the circuit