EasyManua.ls Logo

ircon Modline 5R-3015 - User Manual

Default Icon
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Modline
®
5
Series 52, 56, 5G and
5R Sensors
Infrared Thermometer
Operating Instructions
Rev. L6 Feb 2017
60401

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ircon Modline 5R-3015 and is the answer not in the manual?

Summary

2 Product Description

Model Configuration and Required Selections

Explains how to configure sensor models and select necessary options.

3 Sensor Installation

Sensor Optical Characteristics

Details optical resolution, focusing ranges, and spot size for measurement.

5 Operation

ENGR - Setup of Engineering Functions

Details engineering functions like panel lock, units, and system checks.

6 RS-485 Digital Communications

Engineering Function Command Codes

Lists command codes for engineering functions like keyboard lock and units.

7 Maintenance

Troubleshooting

Guides for identifying and resolving common sensor issues and errors.

8 Applications Guide

Emissivity Settings

Explains how to adjust emissivity for accurate temperature measurements.

ircon Modline 5R-3015 Specifications

General IconGeneral
Accessory TypeInfrared Thermometer
Field of View100:1
Enclosure RatingIP65 (NEMA 4)
Response Time150 ms
Output4-20 mA
Power Supply24 VDC
Storage Temperature-20 to 70°C
Dimensions50 x 50 x 125 mm (2 x 2 x 5 in)
Repeatability±0.5% of reading in °C or °F + 1°C