Installation Dos and Don’ts
• DO check flow to determine maximum throw before locating heads
• DO Plug all heads together with a all cables before burying to test sprinkler connections
• DO Install Cables in a trench or pull a run of 1 inch pipe as conduit
• DO loop excess Cable inside a valve box adjacent to the head
• DO use Cable Tees to branch out your Cables in different directions
• DO use supplied End Plug to seal the last Sprinkler connector
• DO add a second Controller Cable if branching off immediately from the Controller (NOTE: Heads must
be numbered accordingly; e.g. #1-4 on first controller cable and #9-12 on second controller cable)
• DO protect all Digital Sprinkler connections with small valve boxes, buried below turf
• DO use supplied Flex-Pipe for plumbing heads
• DON’T cut and splice IrriGreen Cables
• DON’T pull IrriGreen Cables with a vibra plow … DO pull 1” conduit for the cables if pulling pipe
• DON’T use Teflon tape inside of Irrigreen heads
• DON’T calibrate and program heads before flushing air from all digital AND valve zone piping