Details the Irrigreen2 controller with 16/32 digital zones and 12/24 valve zones.
Describes the digital sprinkler, covering 1 zone and approximately 2000 sq. ft. coverage.
Information on 50ft controller and sprinkler cables with end plugs.
Details on Cable Tee, FlexPipe, and CableLok for system connections.
Overview of optional 1" Ultrasonic Flow Sensor and 24 VAC Transformer.
Specifies 1" mainline pipe requirements in PVC or poly material.
Lists 1" elbows and connectors needed for PVC or poly pipe.
Recommends 6" valve boxes for each digital zone and optional flow sensor.
Details 1" tees with female pipe thread for connecting Flex-Pipe.
Requires minimum 8 GPM flow for optimal throw; 3/4" pipe may restrict flow.
Requires constant pressure between 40-80 PSI for system operation.
Well systems need a constant pressure pump or regulated supply with a PRV.
A 500 Micron filter is required for water sources with particulates.
Place heads to reach farthest corner (25-35 ft); exact placement is flexible due to programming.
Instructions to prevent overlap of spray patterns between zones.
Guidance on using a wheel and flag for initial head placement.
Set the zone startup point (Position 1) at least 10 feet for sufficient pop-up.
Place heads 5 feet or more from the nearest edge.
For narrow zones (<10' wide), place heads along the edge and program a ~180-degree pattern.
Provides throw distances based on PSI, from 40-80 PSI.
One head waters up to ~2000 sq. ft. evenly within a 60-foot diameter circle at 60 PSI.
Illustrates connections for controller, rain sensor, and flow sensor.
Shows sprinkler placement, cabling, mainline, and valve box integration.
Instructions for downloading the IG2 app and connecting to Wi-Fi.
Discusses factors affecting Wi-Fi range and the availability of extenders.
Diagram showing wiring for mobile app, sensors, sprinklers, and valves to the controller.
Details wiring connections for the IrriGreen Flow Sensor.
Explains how to wire sprinklers and valves to the controller.
Explains how to daisy-chain up to eight Digital Sprinklers per run.
Details wiring for Digital Zones 1-8 and 9-16 to the controller.
Instructions on using CableLok and end plugs for secure connections.
All smaller 'male' connectors point back to the Controller.
Larger 'female' connectors always point away from the Controller.
Connects up to eight sprinklers (#1-8) to one controller cable.
Connects sprinklers (#9-16) to a second controller cable.
Digital Sprinklers have Zone Numbers 1-8 and 9-16 assigned at the factory.
Plug all heads together before burying to confirm they run correctly.
Key recommendations include checking flow, plugging heads, using conduit, and protecting connections.
Prohibitions include cutting cables, using vibra plows without conduit, and using Teflon tape internally.
Align arrows on connectors and push together until bottomed out.
Place CableLok Top over connectors, align ridges, then snap both parts into place.
Use a slotted screwdriver to remove the CableLok.
All connections must be protected by a small valve box installed next to the digital head below turf.
Bury head to specified depth, with the top slightly above grade.
Hand-tighten head onto elbow; use Teflon tape on mainline connection, not elbow fitting.
Using Flex-Pipe is required for warranty; improper tape use voids warranty.
The last head on water lines should be disconnected from Flex-Pipe during flushing.
Point disconnected Flex-Pipe out of hole to prevent water from filling it during flushing.
Dig a 15" hole, positioning the head so the cap is about 1/2" above grade.
For slopes, install heads at about a 1/2 angle to the slope.
Flush lines before installing heads and after installation to remove debris and air.
Trapped air acts as an 'air piston', causing calibration errors.
Head damage from debris, sand, or rocks is not covered under warranty.
Identifies terminals for Rain/Soil Sensor 1 and Flow Sensor 1.
Shows terminals for Digital Sprinklers 1-8 (IG Digital 1-8) and 9-16 (IG Digital 9-16).
Details terminals for Master Valve (MV/P 1) and Valve Zones 1-12.
The controller requires 24 VAC, 40 VA power.
Illustrates the connection of the 24 VAC, 40 VA transformer to the controller.
Wiring for Drip/Standard valves to 'Common' and 'Valve 1-4' terminals.
Wiring for Master Valve and/or Pump to 'Common' and 'MV/P' terminals.
A booster may be needed if a pump relay is installed with the Master Valve.
Master valve function: software keeps last head open briefly after master closes to relieve pressure.
Wiring the Master Valve and/or Pump to 'Common' and 'MV/P' terminals.
Connect Normally Closed (NC) sensor wires to 'Sens1' and 'Common' terminals.
Sensors turn the system off when activated.
Indicates system connection to Wi-Fi network status.
Indicates when the system is actively watering.
Indicates a system error has occurred.
Press for 1 second to reset the system and reconnect to Wi-Fi.
Press 3 seconds to run all zones; press 1 second to skip a zone.
Press for 1 second to stop all watering.
Details the meaning of Green and Blue LED blinking for system status.
Describes how to start/skip watering, stop watering, and reset the system.
Procedure to connect directly to the controller's Wi-Fi network for setup.
Instructions on removing the cap and cleaning the filter for performance issues.
Ensure filter markings align with the nozzle opening during reassembly.
Lift the riser and grasp to remove the cap by hand for servicing.
Tighten the torx screw on the cap after reassembly.
Requires 24" PVC before and 12" after the flow sensor for optimal installation.
Install ultrasonic flow sensors at a 45-degree angle to prevent air bubbles.
Use waterproof 'DBY' connections and install splices in a valve box.
Use 3M DBY connectors, ensuring wire nut is fully sealed by gel.
A small valve box (6"-10") is needed for protecting the optional flow sensor.
16-18 gauge two-conductor wire connects the flow sensor to the controller.
Connects sensor leads to the flow sensor wire using supplied grease cap connectors.
Wire the Red Flow Sensor lead to 'Sen1' and the Black lead to 'Common' on the controller.
Details compliance with FCC Part 15 rules and user modification restrictions.
Explains Wi-Fi range limitations due to environment and availability of extenders.
Details the Irrigreen2 controller with 16/32 digital zones and 12/24 valve zones.
Describes the digital sprinkler, covering 1 zone and approximately 2000 sq. ft. coverage.
Information on 50ft controller and sprinkler cables with end plugs.
Details on Cable Tee, FlexPipe, and CableLok for system connections.
Overview of optional 1" Ultrasonic Flow Sensor and 24 VAC Transformer.
Specifies 1" mainline pipe requirements in PVC or poly material.
Lists 1" elbows and connectors needed for PVC or poly pipe.
Recommends 6" valve boxes for each digital zone and optional flow sensor.
Details 1" tees with female pipe thread for connecting Flex-Pipe.
Requires minimum 8 GPM flow for optimal throw; 3/4" pipe may restrict flow.
Requires constant pressure between 40-80 PSI for system operation.
Well systems need a constant pressure pump or regulated supply with a PRV.
A 500 Micron filter is required for water sources with particulates.
Place heads to reach farthest corner (25-35 ft); exact placement is flexible due to programming.
Instructions to prevent overlap of spray patterns between zones.
Guidance on using a wheel and flag for initial head placement.
Set the zone startup point (Position 1) at least 10 feet for sufficient pop-up.
Place heads 5 feet or more from the nearest edge.
For narrow zones (<10' wide), place heads along the edge and program a ~180-degree pattern.
Provides throw distances based on PSI, from 40-80 PSI.
One head waters up to ~2000 sq. ft. evenly within a 60-foot diameter circle at 60 PSI.
Illustrates connections for controller, rain sensor, and flow sensor.
Shows sprinkler placement, cabling, mainline, and valve box integration.
Instructions for downloading the IG2 app and connecting to Wi-Fi.
Discusses factors affecting Wi-Fi range and the availability of extenders.
Diagram showing wiring for mobile app, sensors, sprinklers, and valves to the controller.
Details wiring connections for the IrriGreen Flow Sensor.
Explains how to wire sprinklers and valves to the controller.
Explains how to daisy-chain up to eight Digital Sprinklers per run.
Details wiring for Digital Zones 1-8 and 9-16 to the controller.
Instructions on using CableLok and end plugs for secure connections.
All smaller 'male' connectors point back to the Controller.
Larger 'female' connectors always point away from the Controller.
Connects up to eight sprinklers (#1-8) to one controller cable.
Connects sprinklers (#9-16) to a second controller cable.
Digital Sprinklers have Zone Numbers 1-8 and 9-16 assigned at the factory.
Plug all heads together before burying to confirm they run correctly.
Key recommendations include checking flow, plugging heads, using conduit, and protecting connections.
Prohibitions include cutting cables, using vibra plows without conduit, and using Teflon tape internally.
Align arrows on connectors and push together until bottomed out.
Place CableLok Top over connectors, align ridges, then snap both parts into place.
Use a slotted screwdriver to remove the CableLok.
All connections must be protected by a small valve box installed next to the digital head below turf.
Bury head to specified depth, with the top slightly above grade.
Hand-tighten head onto elbow; use Teflon tape on mainline connection, not elbow fitting.
Using Flex-Pipe is required for warranty; improper tape use voids warranty.
The last head on water lines should be disconnected from Flex-Pipe during flushing.
Point disconnected Flex-Pipe out of hole to prevent water from filling it during flushing.
Dig a 15" hole, positioning the head so the cap is about 1/2" above grade.
For slopes, install heads at about a 1/2 angle to the slope.
Flush lines before installing heads and after installation to remove debris and air.
Trapped air acts as an 'air piston', causing calibration errors.
Head damage from debris, sand, or rocks is not covered under warranty.
Identifies terminals for Rain/Soil Sensor 1 and Flow Sensor 1.
Shows terminals for Digital Sprinklers 1-8 (IG Digital 1-8) and 9-16 (IG Digital 9-16).
Details terminals for Master Valve (MV/P 1) and Valve Zones 1-12.
The controller requires 24 VAC, 40 VA power.
Illustrates the connection of the 24 VAC, 40 VA transformer to the controller.
Wiring for Drip/Standard valves to 'Common' and 'Valve 1-4' terminals.
Wiring for Master Valve and/or Pump to 'Common' and 'MV/P' terminals.
A booster may be needed if a pump relay is installed with the Master Valve.
Master valve function: software keeps last head open briefly after master closes to relieve pressure.
Wiring the Master Valve and/or Pump to 'Common' and 'MV/P' terminals.
Connect Normally Closed (NC) sensor wires to 'Sens1' and 'Common' terminals.
Sensors turn the system off when activated.
Indicates system connection to Wi-Fi network status.
Indicates when the system is actively watering.
Indicates a system error has occurred.
Press for 1 second to reset the system and reconnect to Wi-Fi.
Press 3 seconds to run all zones; press 1 second to skip a zone.
Press for 1 second to stop all watering.
Details the meaning of Green and Blue LED blinking for system status.
Describes how to start/skip watering, stop watering, and reset the system.
Procedure to connect directly to the controller's Wi-Fi network for setup.
Instructions on removing the cap and cleaning the filter for performance issues.
Ensure filter markings align with the nozzle opening during reassembly.
Lift the riser and grasp to remove the cap by hand for servicing.
Tighten the torx screw on the cap after reassembly.
Requires 24" PVC before and 12" after the flow sensor for optimal installation.
Install ultrasonic flow sensors at a 45-degree angle to prevent air bubbles.
Use waterproof 'DBY' connections and install splices in a valve box.
Use 3M DBY connectors, ensuring wire nut is fully sealed by gel.
A small valve box (6"-10") is needed for protecting the optional flow sensor.
16-18 gauge two-conductor wire connects the flow sensor to the controller.
Connects sensor leads to the flow sensor wire using supplied grease cap connectors.
Wire the Red Flow Sensor lead to 'Sen1' and the Black lead to 'Common' on the controller.
Details compliance with FCC Part 15 rules and user modification restrictions.
Explains Wi-Fi range limitations due to environment and availability of extenders.
| Type | Smart Sprinkler System |
|---|---|
| Connectivity | Wi-Fi |
| Warranty | 2 years |
| Control Method | Mobile App |
| Water Efficiency | Up to 50% water savings |
| Features | leak detection |
| Spray Angle | Adjustable 0-360 degrees |
| Spray Distance | Variable |
| Compatibility | Works with most standard irrigation systems |
| Material | Durable plastic |