13
IRRITROL Decoder Systems
7. WI-FI 2-WIRE INSTALLATION
INSTALLATION
A. Specification
B. Mounting
To be mounted indoor or outdoor on a vertical
wall. Do not place or operate in direct sunlight.
Mount near mains outlet or source a cable of
suitable length using IEC320-C7 connector (not
included).
C. Wires
For the 2-wire preferably use solid conductor cable of
minimum cross section:
- For 1000 m cable use minimum 0,75 mm2 (AWG 18)
- For 2000 m cable use minimum 1,50 mm2 (AWG 15)
- For 3000 m cable use minimum 2,00 mm2(AWG 14)
- For 4000 m cable use minimum 2,50 mm2 (AWG 13)
Prepare wire as shown to the right. Connect to
terminals A & B by inserting wires under the plastic
bracket and PCB. Use a PZ2 screwdriver to fasten.
Input 100-240VAC, 50/60Hz, 400mA@230VAC,
800mA@115VAC
Output 36VAC, 280mA
Storage -40°C to +80°C, 10% to 95% RH. Do not store at
extremes for extended periods of time.
Operating -20°C to +60°C. 20% to 90% RH, non-condensing. Do
not operate in direct sunlight.
IP Rating IP54, i.e., protected against dust and splashing water.
Suitable mounting hardware (not included) 3 x
4-5mm flat head wood screws with head size
6-9mm. The length should be adequate for the
surface plus 8mm. On mineral surface use plugs
and screws of suitable length. A mounting template
is found on the reverse side.
Provided antenna must be mounted. Do not replace.