EasyManua.ls Logo

ISCO Signature User Manual

ISCO Signature
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation and Operation Guide
Manual #69-4333-004 of Assembly #60-4334-005
Copyright © 2012. All rights reserved, Teledyne Isco
Revision J, October 2017

Table of Contents

Questions and Answers:

ISCO Signature Specifications

General IconGeneral
BrandISCO
ModelSignature
CategoryMeasuring Instruments
LanguageEnglish

Summary

Foreword

Contact Information

Section 1 Introduction

1.1 Quick Start

Overview of device functions and navigation keys, including keypad and softkey functions.

1.2 Data Integrity

Explains the Signature Flow Meter's unique ability to verify data integrity via special event data types.

1.3 Security

Describes securing the meter with a padlock and a user-selected passcode.

1.4 Compatible Equipment

Details compatible measurement devices and system components for the Signature Flow Meter.

1.5 Identifying Signature Components

Identifies and describes the key physical components of the Signature Flow Meter.

1.6 Controls and Indicators

Familiarizes users with the keypad, display, LED indicator, and other controls.

1.7 Technical Specifications

Provides detailed technical specifications for the Signature Flow Meter and its modules.

Section 2 Setup and Programming

2.1 User Interface

Explains interaction via keypad, display, or Flowlink software.

2.2 The Home Screen

Describes the default run screen displaying current parameter readings and system status.

2.3 Shortcuts

Provides quick access to common commands like level adjustment and data viewing.

2.4 Programming

Guides users through accessing and navigating setup and program menus.

2.5 Program Steps (Menu Trees)

Illustrates the overall menu sequencing for setup and programming.

2.6 Hardware Setup

Explains how the flow meter detects and configures connected devices.

2.7 Configure Options

Details how to set up the measurement site and program parameters.

2.8 Administration

Covers operating preferences and general housekeeping tasks.

2.9 USB Options

Manages data and firmware via a USB flash drive.

2.10 Signature Data in Flowlink

Describes data download and viewing using Flowlink software.

2.11 Verifying Exported Reports

Explains how to verify the authenticity of exported data reports.

General Warnings

Hazard Severity Levels

Explains the three levels of hazard severity used in safety alerts.

Hazard Symbols

1.1 Quick Start

Hardware Setup

Lists the main categories for hardware configuration.

Configure Options

Lists the main categories for configuring settings.

Administration

Lists the main categories for administrative settings.

1.2 Data Integrity

1.3 Security

1.4 Compatible Equipment

1.5 Identifying Signature Components

1.6 Controls and Indicators

1.6.1 Keypad

Explains the function of each key on the keypad and the softkeys.

1.6.2 Display and LED

1.6.3 Backlight and Screen

1.6.4 Display Contrast

1.7 Technical Specifications

2.1 User Interface

2.1.2 Connecting to the Signature with Flowlink

USB Driver for Signature

Instructions for installing the necessary USB driver for computer connection.

Connect window

Explains how to use the Flowlink Connect window to establish communication.

Site Screen

Site Info

Details how to enter site-specific information and save it.

Devices

Program

2.2 The Home Screen

2.3 Shortcuts

2.3.1 Adjust Level

Instructions for setting or updating the level measurement.

2.3.2 Adjust Velocity

Describes how to access velocity grid and laser controls.

2.3.3 Purge

Explains the manual purge function for the bubbler flow meter.

2.3.4 Histograph

Details how the histograph displays measurements in graphical format.

2.3.5 Real-Time Measurement

2.3.6 Report View

2.4 Programming

2.4.1 Off-Screen Content

Explains how to access additional content on screens using arrow keys.

2.4.2 Character Grid

Describes how to use the character grid for alphanumeric entry.

2.4.3 Pull Down Menus

2.5 Program Steps (Menu Trees)

2.6 Hardware Setup

Smart Sensor Setup (TIENet)

View, configure, and scan TIENet devices.

SDI-12 Setup

Scan, add/remove, and configure SDI-12 devices.

Modbus Input Setup

Connect and configure external Modbus input devices.

Modbus Output Setup

Enable SCADA data retrieval via Modbus RS-485.

Modem Setup

Configure modem based on installed type.

2.6.1 Smart Sensor Setup (TIENet)

Perform Scan

Detect system configuration after adding or removing TIENet devices.

Sensor Differences

Lists configuration differences since the last scan.

Configure Measurements

Set up measurement parameters for TIENet devices.

2.6.2 SDI-12 Setup

2.6.3 Modbus Input Setup

2.6.4 Modbus Output Setup

2.6.5 Modem Setup

2.7 Configure Options

Site Setup Options

Set site clock, name, display, units, and power.

Measurement Setup

Set up level, flow rate, and volume measurements.

Adjust Options

Adjust level, velocity, and pH values.

Equations Setup

Create and edit equations based on site conditions.

Data Options

Set up data storage and data push.

Sampler Setup

Configure the sampler interface.

Inputs/Outputs/Alarms Setup

Configure alarms and input/output signals.

Reset Totalizers

Option to reset flow volume totalizers.

Reports/History Setup

Set up report intervals and history logs.

2.7.1 Site Setup

2.7.2 Measurement Setup

Level Input Setup

Select level input and set blanking distances.

Flow Rate Input Setup

Program measurement settings and flow conversions.

Volume Input Setup

Rainfall Input Setup

Load Calculation Setup

2.7.3 Adjust

2.7.4 Equation/Trigger Setup

Defining conditions

Building equations

2.7.5 Data Storage/Push Setup

Data Storage

Set primary and secondary storage rates.

Data Push

Set up data push to a server.

2.7.6 Sampler Setup

2.7.7 Inputs/Outputs/Alarms Setup

Alarm

Configure local, SMS, or server alarms and triggers.

Analog Output

Analog Input

Contact Output

2.7.8 Reset Totalizers

2.7.9 Reports/History Setup

2.8 Administration

Administration Options

Lists all administrative settings such as language, passcode, and diagnostics.

2.8.1 Language Options

2.8.2 Set New Passcode

2.8.3 Update Firmware

2.8.4 Sensor Diagnostics

2.8.5 Display Signature Information

2.8.6 Display License Information

2.8.7 Gather Fault Data

2.8.8 Restore to Factory Defaults

2.8.9 Home

2.9 USB Options

2.9.1 Retrieve Text Reports

2.9.2 Retrieve Data

2.9.3 Update Firmware

2.9.4 Save Current Program

2.9.5 Load Existing Program

2.9.6 Save Signature Information

2.9.7 Gather Fault Data

2.9.8 None of the above

2.10 Signature Data in Flowlink

2.10.1 Event Viewer

Displays event data in tabular format with symbols.

Printing reports

Exporting reports

2.11 Verifying Exported Reports

Section 3 Standard Installation

3.1 Introduction

States that the Signature Flow Meter is used for permanent installations.

3.2 Connecting External Devices

Connects external device cables and the mains line cord.

3.3 Case Bottom Cable Entries

3.3.1 Cable Fittings

3.3.2 Connecting TIENet Devices

3.4 Power

3.4.1 Hard Wiring

Guidelines for using appropriate ID conduit connections for hard wiring.

3.4.2 Line Cord

Recommendations for line cord installation near a mains outlet.

3.4.3 Power Connections

Information on installing the AC power cord kit or wiring.

3.5 Mounting the Signature

3.6 Outdoor Recommendations

3.7 The Bubble Line

3.7.1 Standard Bubble Lines

Lists the available bubble line types, sizes, and lengths.

3.7.2 Comparing Vinyl and PTFE Bubble Lines

Compares vinyl and PTFE bubble lines, highlighting advantages.

3.7.3 Bubble Line Length

Guidance on keeping bubble lines short and using longer ones.

3.7.4 Attaching the PTFE Bubble Line

Attachment

Steps for connecting the PTFE bubble line.

Removal

Steps for removing the PTFE bubble line.

3.7.5 Attaching the Vinyl Bubble Line

3.7.6 Installing the Bubble Line

3.7.7 High-Velocity Flow Streams

3.7.8 Stilling Wells

3.7.9 Flume Bubble Line Fittings

3.7.10 Bubble Line Extensions

3.7.11 Open Channel Installation

3.8 Setting the Level

3.9 TIENet Sensor Installation in a Hazardous Location

Section 4 Portable Installation

4.1 Introduction

States the Signature Portable is equipped with one TIENet receptacle.

4.2 Portable Stand

Describes the portable stand allowing movement and positioning of the Signature.

4.2.1 Adjust Signature to Upward Position

Tools

Lists the tools required for adjusting the Signature to upward position.

4.3 Power

4.3.1 Power Connections

Details the battery connection options for the Signature Portable.

4.3.2 Outdoor Recommendations

Advises on positioning the Signature Portable in unprotected environments.

4.3.3 Battery Installation

Outlines common battery options and installation procedures.

948 lead-acid battery

946 lead acid battery

4.4 Battery Life Expectancy

4.4.1 Major Standard Equipment Settings Effecting Battery Life

Explains how settings like backlight and data rate impact battery life.

4.4.2 Major Optional Equipment Settings Effecting battery Life

4.4.3 Additional Considerations for Battery Life

4.4.4 Calculating Average Current Draw

4.4.5 Battery Life Calculations

Examples

Provides an example calculation for battery life expectancy.

4.4.6 Low Battery Cut Off and Battery Care

4.5 Connect to External Devices

4.5.1 Connecting Devices to the TIENet Receptacle

Details connecting external TIENet devices to the Signature Portable.

Connecting a TIENet receptacle to the Signature Portable

O-Ring and Lubrication for the TIENet receptacle

Three-Hole Cord Grip

Installing a Cable Through a Three-Hole Cord Grip

Instructions for installing a cable through a three-hole cord grip.

Connecting the Rain Gauge

Section 5 Equipment Options

AC Power Cord Kit /AC Wiring (Applies to Permanent Installation Only)

Information on installing the AC power cord kit for permanent installations.

Battery Backup (Applies to Permanent Installation Only)

Details on installing the battery backup option for permanent installations.

Mechanical Totalizer

Information on the seven-digit, non-resettable mechanical counter.

External Desiccator

Describes the external desiccator used with certain sensors.

Ultrasonic Level Sensor

Information on the TIENet 310 Ultrasonic Level Sensor.

Bubbler Level Sensor

Details on the TIENet 330 Bubbler Level Sensor.

Contact Output Card (TIENet 304)

Information on the TIENet 304 contact output card.

Analog Input Card (TIENet 307)

Details on the TIENet 307 analog input card.

Analog Output Card (TIENet 308)

Information on the TIENet 308 analog output card.

pH and Temperature Device

Details on the TIENet 301 pH and temperature sensor.

Sampler Interface

Information on the TIENet 306 Sampler Interface.

TIENet Expansion Box

Information on the TIENet Expansion Box for additional connections.

Isco Flowlink Software

Details on the Flowlink software for data acquisition and analysis.

Ethernet Modem

Information on the Ethernet modem for remote communication.

Cellular Modems

Details on CDMA and GSM cellular modems.

Laser Doppler Velocity Sensor

Information on the TIENet 360 LaserFlow velocity sensor.

Continuous Wave Doppler Velocity Sensor

Details on the TIENet 350 Area Velocity Sensor.

5.1 AC Power Cord Kit /AC Wiring (Applies to Permanent Installation Only)

5.2 Battery Backup (Applies to Permanent Installation Only)

5.3 Power Loss Alarm

Contact Output Card (TIENet 304)

Use of the Contact Output Card for power loss indication.

Analog Output Card (TIENet 308)

Use of the Analog Output Card for power loss indication.

12 Volt DC Output

Voltage levels indicating power status.

Signature Power Loss Alarm Box (60-5324-024)

Description of the power loss alarm box.

5.4 Mechanical Totalizer

Installation

Steps for installing the mechanical totalizer.

5.5 External Desiccator

5.6 TIENet® Devices

5.6.1 Ultrasonic Level Sensor

Information on the TIENet 310 Ultrasonic Level Sensor.

5.6.2 Bubbler Level Sensor

5.6.3 Laser Doppler Velocity Sensor

5.6.4 Continuous Wave Doppler Velocity Sensor

Optimal drying power

5.6.5 Sampler Interface

5.6.6 pH and Temperature Device

5.6.7 TIENet Expansion Box

5.6.8 Contact Output Card (TIENet 304)

Tools required

To install a card:

Configuration

Home Display

5.6.9 Analog Input Card (TIENet 307)

Tools required

Lists tools required for card installation.

To install a card:

Step-by-step instructions for installing an option card.

Channels

Configuration

5.6.10 Analog Output Card (TIENet 308)

Tools required

Lists tools required for card installation.

To install a card:

Step-by-step instructions for installing an option card.

Configuration

5.7 Isco Flowlink Software

5.8 Ethernet Modem

5.8.1 Ethernet Modem Configuration

Hardware Setup

Lists the main categories for hardware configuration.

Modem Setup

Shows the modem setup screen for communication settings.

5.8.2 Network Firewall Settings

5.9 Cellular Modems

5.9.1 CDMA Modem

Details on the CDMA modem for automatic data push.

5.9.2 GSM Modem

5.9.3 Installing the Cellular Modem

5.9.4 Cellular Modem Configuration

Section 6 Maintenance and Servicing

6.1 Maintenance

Provides recommended maintenance checks for ensuring proper operation.

6.2 Cleaning

6.3 Firmware Updates

a. Update Signature Firmware

b. Update TIENet (Smart Sensor) Firmware

c. Bootcode

6.4 Accessing the Interior

6.5 Desiccant

6.5.1 Internal Desiccator

Instructions for replacing the internal desiccant bag.

6.5.2 External Desiccator

Renewing loose desiccant

6.6 Troubleshooting

6.6.1 Signature Flow Meter

Troubleshooting symptoms, causes, and actions for the Signature Flow Meter.

6.6.2 TIENet 300 Connector Case

6.6.3 TIENet 301 pH/Temp

6.6.4 TIENet 304 Contact Output Card

6.6.5 TIENet 307 Analog Input Card

6.6.6 TIENet 306 Sampler Interface

6.6.7 TIENet 308 Analog Output

6.6.8 TIENet 310 USLS

6.6.9 TIENet 330 Bubbler Air Supply of Bubbler

Output of Air Pump

Describes the air pump output and its components.

Normal Operation

Details the normal operation of the air purge solenoid.

Purge Cycle

Explains the function of the purge cycle in the bubbler system.

Autozero

Describes the automatic autozero process for the pressure transducer.

6.6.9 TIENet 330 Bubbler Module

6.7 330 Bubbler Installation

6.7.1 Preparation: Non-Bubbler

Steps for preparing the unit for new bubbler installation.

6.7.2 Preparation: Existing Bubbler

6.7.3 Installation Procedure

6.8 Front Cover Replacement

6.9 System Reset

6.10 Service and Repair

Appendix A Replacement Parts

A.1 How to Order

Information on how to purchase replacement parts.

A.2 Signature Flow Meter

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST

A.3 330 Bubbler

REPLACEMENT PARTS LIST

Appendix B Options and Accessories

B.1 Ordering Information

How to purchase options and accessories.

B.2 Signature Flow Meter Accessories

Lists various accessories for the Signature Flow Meter.

B.3 Power Accessories

B.4 TIENet Accessories

B.4.1 Internal to Signature

Lists internal TIENet option cards.

B.4.2 Sensor and Cabling

Lists TIENet connection cables and fittings.

B.4.3 301 pH/Temperature Device with Signature Connection Ending in Unterminated Leads

Details the 301 pH/Temperature Device with specific cable connection.

B.4.4 301 pH/Temperature Device with Signature Connection Ending in TIENet Plug

Details the 301 pH/Temperature Device for portable use.

B.4.5 306 Sampler Interface Cable with Signature Connection Ending in Unterminated Leads

Lists the sampler interface cable for Signature connection.

B.4.6 306 Sampler Interface Cable with Signature Connection Ending in TIENet Plug.

B.4.7 310 Ultrasonic Level Sensor with Signature Connection Ending in Unterminated Leads.

B.4.8 310 Ultrasonic Level Sensor with Signature Connection Ending in TIENet Plug.

B.5 330 Bubble Options and Accessories

B.5.1 350 Area Velocity Sensor with Signature Connection Ending in Unterminated Leads.

B.5.2 350 Area Velocity Sensor with Signature Connection Ending in TIENet Plug.

B.5.3 360 LaserFlow Velocity Sensor with Signature connection ending in unterminated leads.

B.5.4 360 LaserFlow Velocity Sensor with Signature Connection Ending in TIENet Plug.

B.6 Modems

B.7 Manuals

B.8 Sensor Mounting Rings

B.8.1 Spring Rings

Lists spring rings for different pipe sizes.

B.8.2 Scissor Rings

Appendix C Modbus Output Protocol

C.1 Introduction

Overview of Modbus protocol and its application to the Signature Flow Meter.

C.2 Operation

Explains how Modbus drivers link to remote devices.

C.3 Configurations

C.4 Glossary of Terms

C.5 Signature ASCII or RTU Address

C.6 Register Definitions

C.6.1 Modbus Registers

Table of Modbus output registers for the Signature Flow Meter.

Appendix D Material Safety Data Sheets

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Related product manuals