EasyManua.ls Logo

Iseo 1NCA Mullion - User Manual

Default Icon
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALY
Tel. +39 0364 8821
iseo@iseo.com
Non contractual document. Subject to change. Cod. KW21870 - 07/05/2023
1NCA Mullion Installation Guide (EN) - © 2023 Iseo Serrature S.p.a.
1NCA Mullion
INSTALLATION GUIDE (EN)
WARNINGS
EC Declarations of conformity available at:
https://www.iseo.com/it/en/download
ULTIMATE ACCESS
TECHNOLOGIES
Read this manual prior to use the device in order to ensure a safe and proper use.
Preserve this manual as future reference.
The installation and maintanance of the device must be carried out by qualied technical staff, adequately
trained by ISEO.
The instructions should be carefully followed during installation. These instructions and any maintenance
instructions should be passed on by the installer to the user.
No modications of any kind are permitted, except for those described in these instructions.
The product must be destined only for the use for which it is expressly designed and therefore as a
credential reader for residential, commercial and light industry locations. Any other use is considered
improper and dangerous.
The electrical connection must be made according to the constructor's instructions and respecting the
regulations in force.
In the event of a failure and/or poor operation, remove the power supply using the main switch and do not
tamper with it. For all repairs, exclusively contact a technical assistance center authorized by the constructor.
Disconnect the power supply before carrying out any technical service that involves opening or accessing
the internal parts of the product.
PACKAGE CONTENTS
TECHNICAL DATA
1NCA Mullion
Torx key T8
Fixing bracket
Spacer with screws
Cod.0000IS00354
(Optional - to be
separately ordered*)
Included in Mullion
Lockbus for Stylos
replacement
2 x Screws (3,5x25
countersunk head)
and wall plugs (5x25)
4 x Screws
(3x8)
2 x Screws
(3,5x25
at-head)
1 x Fixing bracket Torx
screw (M2,5x5)
PRODUCT:
1NCA MULLION
APPLICATION:
Credential reader to open any electrical device
MODELS:
- 1NCA Mullion Lockbus
- 1NCA Mullion Relay
- 1NCA Mullion Keyboard Lockbus
- 1NCA Mullion Keyboard Relay
COMMUNICATION INTERFACES:
- Bluetooth 5.0 - Frequency 2,40 - 2,4835 GHz
Maximum power: < 10 mW
HOUSING:
To be xed to the wall by the multi-holes xing
bracket
OPERATING TEMPERATURES:
- RFID reader frequency 13,553 - 13,567 MHz,
maximum magnetic eld: < 40 µA/m (measured
at 10m at the maximum power capacity).
Compatible to:
• ISO/IEC 14443 Type A and Type B cards
• MIFARE Classic & DESFire (EV1, EV2, EV3)
ISEO Cards & Keyfobs (min.20mm antenna diam.)
CERTIFICATIONS:
Compliance to RED, European and UK directives
concerning radio equipment regulations
IP Grade: IP66
- Working temperature: -20°C/+60°C
- Storage temperature: -20°C/+70°C
- H.R.: Max. 95% with no condensing
TAMPERING DETECTION (*):
- Tamper on the back of the housing
- Detects if the Mullion is removed from the wall
PIGTAIL CABLE:
SOFTWARE COMPATIBILITY:
- ARGO
- V364 (no Keyboard version)
- Luckey and LSA
POWER SUPPLY:
9÷24 Vdc - Max power consumption = 1W
KEY FEATURES:
- 12 keys capacitive keyboard (keyboard models)
- Tri-color LED (green, red, blu)
- Multifrequencies buzzer
- Automatic low power mode (max 0,4mW)
- 5mt data and power cable included (AWG22)
- Multi-holes xing bracket
LOCKBUS:
- 3 wires multipoint serial bus for power and data
- Self-adjusting power supply from 9Vdc to 24Vdc
(recommended voltage 24 Vdc)
- Secure device authentication among readers
and actuators and encrypted data transmission
- Max cable length 100 mt
RELAY:
- Output power relay 30Vac/dc - 2A
- N.O. (normally open) contact available
- Estimated operation’s cycles: 100.000
BATTERY:
Backup RTC (reat time clock) internal battery
- CR2032 3V Lithium coin battery
3V
CR2032
Lithium
Risk of explosion if the battery is replaced with an incorrect type.
Dispose of batteries according to your local environmental laws and guidelines.
Battery replacement must be carried out by qualied technical staff.
*
MODELS & VERSIONS
RFID + Keyboard
- Lockbus (*)
- Relay
1NCA Mullion
Keyboard
1NCA Mullion
(*) Compatible with Stylos
- Polyetylene grey 5mt shielded cable AWG22
- 2 twisted pair conductors 2x2x0,34mmq - 250V
- Cable external diameter 7,6mm
- Wires colors and signals:
• WHITE = Power supply positive +
• BROWN = Power supply negative
YELLOW = Lockbus / Relay N.O.
• GREEN = Relay COM
DIMENSIONS
48
48
10
26
146
146
60
83,5 (*)
MULLION RELAY: ELECTRICAL CONNECTION EXAMPLE
Fixing Bracket
Wall xing holes
Spacer
Wall xing holes
Spacer
thickness
UM = mm
Vin
230Vac
Relay N.O
Vout
12Vdc
Power
supply
Mullion
Relay
WHITE Power supply +
BROWN Power supply
YELLOW Relay N.O.
GREEN Relay COM
(*) Stylos compatible holes
(*) Tamper will be managed in future software application.
RFID
- Lockbus (*)
- Relay
Question and Answer IconNeed help?

Do you have a question about the Iseo 1NCA Mullion and is the answer not in the manual?

Overview

The ISEO 1NCA Mullion is a versatile access control device designed for both standalone gate and on-line door applications. It functions as a keypad and RFID reader, offering multiple authentication methods and robust security features.

Function Description:

The 1NCA Mullion serves as an access control terminal, allowing users to gain entry using a keypad (PIN code), RFID card/tag, or a combination of both. It can operate in two primary modes:

  • Standalone Gate Application: In this configuration, the Mullion directly controls a gate actuator. Users authenticate at the Mullion, which then sends a signal to the actuator to open or close the gate. This setup is ideal for single-point access control without requiring a central management system.
  • On-Line Door Application: When integrated into an on-line system, the Mullion connects to a central access control panel (e.g., ISEO Atlas) via Lockbus. In this mode, access decisions are made by the central panel, allowing for more complex access policies, real-time monitoring, and centralized user management. The Mullion acts as an input device, sending authentication data to the panel.

The device supports various RFID standards, making it compatible with a wide range of existing access cards and tags. Its robust design, including IP66 certification, ensures durability and resistance to environmental factors, making it suitable for outdoor installations.

Important Technical Specifications:

General:

  • Model: 1NCA Mullion Lockbus
  • Authentication: Keypad, RFID, or both
  • LED Indicators: Red, Green, Blue for status indication
  • Power Consumption: 1W (maximum)
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -20°C to +70°C
  • Humidity: 10% to 90% (non-condensing)
  • IP Rating: IP66 (when correctly assembled)
  • Dimensions: 48mm (W) x 146mm (H) x 26mm (D)
  • Weight: Approximately 0.2kg

Keypad:

  • Type: Capacitive, 12 keys (0-9, *, #)
  • Features: Buzzer for audible feedback, multi-frequency operation
  • PIN Code Length: 4 to 8 digits
  • Tamper Protection: Detects removal from the wall

RFID Reader:

  • Frequency: 13.56 MHz
  • Supported Standards:
    • MIFARE Classic & DESFire (EV1, EV2, EV3)
    • ISO 14443 Type A
    • ISO 15693
    • NFC (ISO 18092)
    • BLE (Bluetooth Low Energy) 2.4835 GHz
  • Read Range: 10mm (maximum, varies with tag type and environment)
  • Certifications: CE, UKCA, RED, European and UK directives relative to radio equipment

Connectivity:

  • Lockbus: Proprietary communication bus for connection to ISEO access control panels (e.g., Atlas) or gate actuators.
  • RS485: For on-line systems, enabling communication with a central controller.

Electrical Connections:

  • Power Supply: 12Vdc (minimum 0.4W, maximum 1W)
    • White wire: Power supply +
    • Brown wire: Power supply -
  • Lockbus: Yellow wire
  • Green wire: Not used (in some configurations)

Internal Battery:

  • Type: CR2032 - 3V Lithium coin battery
  • Lifespan: 5 to 10 years (estimated)
  • Purpose: Powers the Real Time Clock (RTC) and retains configuration data during power outages.

Usage Features:

  • Multiple Authentication Methods: Users can choose between PIN code entry, RFID card/tag presentation, or a combination of both for enhanced security.
  • Configurable Access Policies: Depending on the system (standalone or on-line), access policies can be configured to grant or deny entry based on time, user groups, and specific credentials.
  • LED Feedback: The device provides clear visual feedback through its LEDs:
    • Blue LED: Indicates successful operation (e.g., valid key exchange, access granted).
    • Red LED: Indicates an error or unsuccessful operation (e.g., invalid key exchange, access denied).
    • Green LED: Typically indicates a ready state or successful authentication.
  • Audible Feedback: A buzzer provides audible confirmation for key presses and authentication events.
  • Tamper Detection: The Mullion is equipped with a tamper switch that triggers an alarm if the device is forcibly removed from its mounting surface, enhancing physical security.
  • Easy Key Exchange (Standalone Mode): In standalone gate applications, coded keys can be exchanged by connecting the Mullion to the actuator and pressing a button for 3 seconds, simplifying initial setup.
  • Compatibility with Stylos: The Mullion Lockbus is designed to be a replacement for Stylos devices, with a spacer included for easy installation in existing Stylos mounting holes.
  • Robust Design: The IP66 rating ensures the device is protected against dust ingress and powerful water jets, making it suitable for outdoor and harsh environments.

Maintenance Features:

  • Battery Replacement: The internal CR2032 3V Lithium coin battery, which powers the Real Time Clock (RTC) and retains configuration, needs to be replaced approximately every 5 to 10 years.
    • Procedure: Involves carefully disassembling the Mullion by removing screws, disconnecting the internal cable, and replacing the battery.
    • Important Note: Battery replacement must be performed by qualified technical staff. There is a risk of explosion if the battery is replaced with an incorrect type. Used batteries must be disposed of according to local environmental laws.
    • IP66 Protection: Incorrect disassembly of the Mullion can compromise its IP66 certification, potentially leading to water or dust ingress.
  • Firmware Updates: While not explicitly detailed in the provided excerpts, access control devices typically support firmware updates to introduce new features, improve performance, or address security vulnerabilities. These updates would usually be performed by qualified technicians.
  • Troubleshooting: The manual provides warnings and instructions for proper installation and usage, which are crucial for preventing malfunctions and ensuring the longevity of the device. For instance, it advises against performing any operation that involves opening or accessing internal parts unless specifically instructed by the manufacturer.
  • Cleaning: The exterior of the device can be cleaned with a damp cloth. Avoid using abrasive cleaners or solvents that could damage the casing or keypad.

Iseo 1NCA Mullion Specifications

General IconGeneral
BrandIseo
Model1NCA Mullion
CategoryIP Access Controllers
LanguageEnglish