3. Parameter Setting Key Description
~
g
1.
Press one time to increase Number.
1.
Press one time to enter Parameter
or
parameter value.
2.
Hold Press to decrease number 2. Press 2 Seconds to Save Parameter value
V.
Parameter List
No
Item Range Unit Lock
Over
Post
Twin
Chain Special
-stitch -lock -bed -needle -stitch
Pl
Sewing
machine maximum
2 - 80
*lO0spm 40 60 20
25
40 8
speed
P2 Sewing machine positioning
10-
25
*lOspm 20 20 20 20 20 10
speed
P3
Motor's pulley dimension
50 - 100 (notel)
*lmm
75
85
65 65
75
50
P4
Machine's pulley dimension
50 - 120 (notel)
*lmm
75
55
65
80
65
120
P5
Pulley ratio setting mode
ON:
Refer motor pulley ratio
--
ON ON ON ON ON
ON
measurement
OFF:
Refer
P3
and
P4
P6
Virtual needle down
ON:
With the function
--
OFF OFF OFF OFF
OFF OFF
positioning function
OFF:
No
such
function
P7
The angles between virtual
70 - 250 (notel)
*1"
180 180 180 180 180 180
needle
down
positioning
point and needle up signal
PS
Soft start stitches
0 -
19
* 1 stitch 0 0 0 0 0 0
P9
Soft start speed
25
- 200 (notel) *lOspm 40 40
25
40 40 40
Fl
Synchronizer mode or
ON:
Clutch mode(No E.1)
--
OFF OFF OFF OFF
OFF OFF
Clutch mode
OFF:
Synchronize
mode
F2 Motor rotating direction
ON:
Counterclockwise
--
ON
OFF
ON ON
OFF OFF
OFF:
Clockwise
F3
Motor static brake function
0:
No such function
--
0 0 0
0 0
0
1 - 20: The bigger value
means the more
powerful braking
force.
F4 Accelerating speed slope 1 -
8:
The bigger value
--
3 3 3 3 3 6
choice
means slowly
accelerating.
4