Do you have a question about the ISOIL SBM 32 CF and is the answer not in the manual?
Lining Material | PTFE |
---|---|
Accuracy | ±0.5% of reading |
Type | Magnetic Flow Meter |
Nominal Diameter | 32 mm |
Electrode Material | Stainless Steel |
Measurement Range | 0-10 m/s |
Output Signal | 4-20 mA |
Power Supply | 24 VDC |
Details the product warranty terms and conditions, including coverage and exclusions.
Provides a general overview of ISOIL positive displacement meters and their application.
Explains how the liquid flow causes the rotor to revolve and transmit movement to the register.
Outlines essential safety instructions for installation, operation, and maintenance personnel.
Specifies that the meter must only be operated by trained and authorized personnel.
Details operator responsibilities regarding safety standards and handling hazardous substances.
Provides critical safety steps before performing any maintenance or servicing operations.
Lists precautions for meter calibration and installation for optimal performance.
Lists essential points to ensure correct and safe installation of the meter counter.
Details critical checks and procedures before starting up the meter for the first time.
Explains how to separate the meter into its main assemblies for maintenance.
Provides step-by-step instructions for dismantling the main components of the meter.
Details the procedure for removing the rotor assembly and its associated parts.
Describes the calibrating mechanism and its general maintenance considerations.
Outlines the procedure for calibrating the meter using a square key and stop pin.
Lists suggested lubricating oils and their temperature ranges for the calibrating mechanism.
Explains how to test the meter after overhaul using proving systems and calculating error.
Describes the function and maintenance of the optional strainer and air eliminator.
Provides detailed service instructions for the strainer, including cleaning and parts replacement.
Details the servicing procedure for the air eliminator, including pressure discharge and component removal.
General guidance on assembling the meter after maintenance, emphasizing cleanliness.
Step-by-step instructions for assembling the measuring chamber and its internal components.
Instructions for assembling the calibrating mechanism onto the measuring chamber.
Guidance for handling extraordinary maintenance needs or system faults.
Provides instructions for storing the meter properly when not in use for extended periods.
Emphasizes the use of original spare parts and the manufacturer's responsibility.
Provides a schedule for visual inspections and detailed meter checks over time.
Details common faults, their possible causes, and corrective actions for troubleshooting.