Manuale Istruzioni Unità Refrigerante VE150
VE150 Cooling Unit Instruction Manual
Manuel d’Instructions Unité Réfrigérante VE150
Bedienungsanleitung Kühleinheit VE150
Zona Artigianale snc
47866 – Sant’Agata Feltria (RN) – ITALY
Tel. +39 0541 848030 Fax +39 0541 848563
info@indelwebastomarine.com
www.indelwebastomarine.com

Questions and Answers

  • A
    Adam BeckerAug 2, 2025
    What to do if the Isotherm Freezer is running but not cooling?
    • S
      Sara CampbellAug 2, 2025
      If your new Isotherm Freezer runs but doesn't cool, it might be due to a gas leak or insufficient gas in the system. Check the connectors and tighten them by hand until snug, then use a tool for a quarter turn, but don't overtighten as this can damage them and require replacement. If there's a gas leak (indicated by lower than normal consumption), locate it by pressurizing the system with a maximum of 5 bar of nitrogen and then seal the leak by welding.
  • J
    Jessica MasonAug 9, 2025
    Why won't my Isotherm ve150 start, even though it was working before?
    • J
      Juan MillerAug 9, 2025
      If your Isotherm Freezer that previously worked won't start, the issue might stem from low voltage in the main power supply. Check the electrical connections to ensure they are secure. If the power supply isn't the issue, the compressor may need replacing.
  • V
    Vanessa ChapmanAug 17, 2025
    What to do if Isotherm ve150 runs for a few seconds then stops?
    • C
      Crystal WoodAug 17, 2025
      If a new Isotherm Freezer runs for only a few seconds and then stops, the cause depends on the duration it runs. If it runs for less than 0.5 seconds, remove excess gas from the unit, considering that gas pressure may depend on the temperature. If it runs up to 2 seconds, refer to the section "L'unità lavora per qualche secondo - Unità nuova". If it operates for 3 to 5 seconds, replace the fan.
  • C
    Charles CastanedaAug 25, 2025
    How to fix a new Isotherm ve150 Freezer that won't start?
    • A
      Amanda JohnsonAug 25, 2025
      If a new Isotherm Freezer doesn't start, it could be due to several reasons. The main power supply voltage might be too low, so check the cable connections. If the battery is older than 3-4 years, try recharging it, but it might need replacement. Also, check the cables for oxidation and replace them if necessary.

Summary

Warnings and General Safety

Safety Instructions and Precautions

Essential safety guidelines for installation, operation, and maintenance of the cooling unit.

Electrical Connections

Power Supply and Wiring

Details on connecting the unit to power sources, including fuse and cable specifications.

Troubleshooting Common Issues

Cooling Unit Does Not Start

Diagnosing and resolving issues when the cooling unit fails to start.

Advanced Troubleshooting

Intermittent Operation and Gas Issues

Resolving problems related to short operation cycles and refrigerant levels.

Cooling Performance Issues

Diagnosing why the unit is not cooling effectively, including gas leakage.

Troubleshooting Continued

Isotherm ve150 Specifications

General IconGeneral
Defrosting SystemManual
Volume/Capacity150 liters
Dimensions (HxWxD)843 x 600 x 600 mm
Temperature Range-18°C to -22°C
Weight73 lbs (33 kg)