Page #33 background imageLoading...
Page #33 background image
30
TROUBLESHOOTING
Problem Cause Solution
Generator will not start
No fuel Add fuel
Faulty spark plug Replace spark plug
Unit loaded during start up Remove load from unit
Generator will not start;
Generator starts but runs roughly
Low oil level
Fill crankcase to the proper level
Place generator on a at, level surface
Choke in the wrong position Adjust choke
Spark plug wire loose Attach wire to spark plug
Generator shuts down during operation
Out of fuel Fill fuel tank
Low oil level
Fill crankcase to the proper level. Place
generator on a at, level surface
Generator cannot supply enough power or
overheating
Generator is overloaded
Review load and adjust. See “Power
Management”
Insuf cient ventilation
Check for air restriction. Move to a well
ventilated area
No AC output
Cable not properly connected Check all connections
Connected device is defective Replace defective device
Circuit breaker is open Reset circuit breaker
Loose wiring Inspect and tighten wiring connections
Other Contact the help line
Repeated circuit breaker tripping
Overload
Review load and adjust. See “Power
Management”
Faulty cords or device
Check for damaged, bare or frayed wires.
Replace defective device