Itho Daalderop
RFT RH sensor BAT
Installation & Use
Question and Answer IconNeed help?

Do you have a question about the Itho Daalderop 04-00046 and is the answer not in the manual?

Itho Daalderop 04-00046 Specifications

General IconGeneral
Product TypeWireless RF Module
Model Number04-00046
BrandItho Daalderop
CompatibilityItho Daalderop ventilation systems
Frequency868 MHz

Summary

Introduction

Important Notes and Warnings

Highlights definitions of Warning, Caution, Note, and Tip for understanding manual instructions and hazards.

Product Information

2.1. Product Description

Provides details on the sensor's function, optimal placement for humidity control, and its communication with the ventilation unit.

2.2. Technical Specifications

Details dimensions, weight, housing, power supply, battery life, sensor type, measurement range, and RF specifications.

2.3. Application

Lists compatible ventilation units that the wireless sensor can be connected to.

Installation

Installation Location Advice

Provides critical placement advice for bathrooms and utility rooms, and warns against placement near windows or doors.

Battery Life and Indicators

Explains the expected battery life of approximately two years and the red LED indicator for low battery.

Mounting the Sensor - Part 1

Details opening the sensor by releasing the latch and attaching the sensor to the wall using supplied screws.

Mounting the Sensor - Part 2

Details inserting batteries into the compartment and placing the cover back on the installed wall support.

Operation

4.1. Status

Explains the meaning of the status LED colors and flashes for the ventilation unit and sensor.

4.1.1. Ventilation Speeds

Details how to set different ventilation speeds using the touch button and the corresponding LED states.

Automatic Speed and Timer Settings

Explains automatic modes, duration limits for speeds, and how to revert to Auto speed after a set time.

4.1.2. Auto Night Speed

Describes the Auto Night speed setting for increased ventilation during the night and its manual activation.

4.1.3. Dirty Filter Indication

Explains how the system indicates dirty filters via wireless messages and the sensor's orange LED status.

4.1.4. Resetting Filter Indication

Provides instructions to reset the dirty filter indication after cleaning or replacing filters.

Use

5.1. Pairing

Guides on how to link the sensor to the ventilation unit, including pairing status indicators.

5.2. Configuration Settings

Details how to enter configuration mode and set parameters like room type and duration of ventilation speeds.

Configuration Setting Options

Presents detailed options for room type, maximum duration high speed, and non-automatic selection.

Configuration Setting Details

Summarizes settings for room type and duration of high-speed and non-automatic ventilation selections.

5.3. User Settings

Explains how to enter user settings mode and configure sensitivity to rising humidity.

User Setting Options

Details user settings for relative humidity sensitivity, including default and alternative options.

Service & Maintenance

Maintenance and Troubleshooting

Provides guidance on sensor maintenance, battery replacement, and interpreting red status LED for RF malfunctions.

Warranty

Recycling

Declarations