Aerostat Guardian 5100650-M Rev 2 26
5.1 Specifications
Input Voltage
120 VAC, 60 Hz, 0.5A (fan low, heater/light off); 2.5A (fan high, heater/light
on) 230 VAC, 50 Hz, 0.2A (fan low, heater/light off); 1.5A (fan high, heater/
light on)
Discharge 3.0 sec @ 18” center blower position; fan high-no diffusers (1000-100V)1
Balance 0 ±5V @ 18” from blower face
Ion Emission AC Ionization
Coverage 2’ x 4’ area
Cleanroom Class Meets ISO 14644-1 Class 5; Fed std. 209E Class 100
Emitter Points Stainless Steel
Controls
Fan speed control knob BLOWER ON; on/off switch HEATER & TASK
LIGHT
Indicator Lights
Orange IONIZATION STATUS; orange within on/off switches HEATER &
TASK LIGHT
Air Volume 150-300 cfm (low to high), combined 3-fan output
Heated Air Temp
25°F (14°C) fan low; 11°F (6°C) fan high measured @ 6” in front of center
fan above ambient;
Audible Noise 50 dBA fan low; 60 dBA fan high
Operating Env. Temperature 32-122°F (0-50°C); humidity 30-70% RH, non-condensing
Ozone 0.02 ppm, measured @ 12” in front of unit2
Lamp 13W twin tube, compact fluorescent, 1650 lumen total task light output
Air Filter 30 ppi open cell polyurethane foam (optional)
Mounting Adjustable brackets and S-hooks provided
Enclosure Powder-coated white enamel aluminum
Weight 16 lb (7.3 kg)
Dimensions 42.75W x 4H x 6.75D in. (108.6 x 10.2 x 17.1 cm)
Warranty Two year limited warranty
Certifications RoHS Complian 230V, 50 Hz 120V, 60 Hz