MODEL
SUPERAC
93 105 150 190 230 290
345
405
Rated output 93 104.
7
151.
2
192 233 291
349
407 kW
Furnace thermal output 103 115.
5
167 211 257 320
384
449 kW
Furnace counterpressure 0.5 0.7 1.2 1.2 1.5 2.3 3.3 4.4 mbar
Water side loading loss (∆t
15°C)
4.5 5.6 11.8
6.9 10 16.3
23 31 mbar
Boiler water content 119 119 155 228 228 285
276
329 dm3
Max boiler working pressure 5 5 5 6 6 6 6 6 bar
Min boiler return temperature
allowed
50 50 50 50 50 50 50 50 °C
Max boiler temperature
allowed
100 100 100 100 100 100
100
100 °C
Weight in empty conditions 270 280 340 450 460 590
630
700 kg
MODEL
SUPERAC
465 520 580 695 810 930 1045
Rated output 465 523 581 700 820 940 1060 kW
Furnace thermal output 511 577 637 771 899 1027 1156 kW
Furnace counterpressure 3.3 4.3 4.8 4.5 5.6 5.4 6 mbar
Water side loading loss (∆t
15°C)
18 22 28 18 25 33 40 mbar
Boiler water content 402 402 476 697 795 733 817 dm3
Max boiler working pressure 6 6 6 6 6 6 6 bar
Min boiler return temperature
allowed
50 50 50 50 50 50 50 °C
Max boiler temperature
allowed
100 100 100 100 100 100 100 °C
Weight in empty conditions 900 910 1000
1270 1400 1500 1650 kg
MODEL
SUPERAC
1220
1450
1860
2330 2910 3490 4070
Rated output 1240
1480
1890
2360 2960 3550 4150 kW
Furnace thermal output 1349
1606
2056
2570 3213 3855 4497 kW
Furnace counterpressure 6.5 6.8 7 7.2 7.5 7.8 9 mbar
Water side loading loss (∆t
15°C)
36 54 45 70 64 90 120 mbar
Boiler water content 1277
1372
2010
2163 3155 3292 4839 dm3
Max boiler working pressure 6 6 6 6 6 6 6 bar
Min boiler return temperature
allowed
50 50 50 50 50 50 50 °C
Max boiler temperature
allowed
100 100 100 100 100 100 100 °C