Do you have a question about the IXXAT USB-to-CAN V2 and is the answer not in the manual?
Details common features across all IXXAT USB-to-CAN V2 Plugin interfaces, including USB 2.0 Hi-Speed and connection type.
Lists features that vary based on the specific CAN interface model, such as supported field buses and galvanic isolation.
Guide to installing the VCI driver for Windows and ECI for Linux, essential for device operation.
Step-by-step process for physically installing the interface into a PC, including safety precautions.
Details USB and field bus connector pinouts and types for different models, including galvanic isolation aspects.
Explains the function and meaning of USB, CAN, and LIN status LEDs for monitoring communication activity.
Provides physical dimensions, mounting hole specifications, and overall overview of the device.
Recommends suitable fasteners and describes two orientations for mounting the CAN interface device.
Information on CAN bus termination requirements and an available accessory for bus termination.
Details on LIN interface configuration, required power supply, and power consumption limits.
Comprehensive technical specifications including USB, CAN, LIN, power, dimensions, and environmental data.
Guidance on accessing support resources, FAQs, and the procedure for returning hardware.
Details FCC rules, Class B device instructions, EMC guidelines, and EC Declaration of Conformity.
| USB Version | USB 2.0 |
|---|---|
| CAN Channels | 2 |
| Power Supply | Via USB |
| Supported CAN Standards | CAN 2.0 A/B, ISO 11898-2 |
| CAN Interface | High-speed CAN |
| Galvanic Isolation | Yes |
| CAN Connector | D-Sub 9-pin (male) |
| Supported Operating Systems | Windows, Linux |
| Operating Voltage | 5V from USB |
| CAN Bit Rates | 10 kbit/s to 1 Mbit/s |
| Operating Temperature | -20°C to +70°C |