The JA-154E Wireless access module with LCD, RFID and keypad
The JA-154E wireless access module with LCD, RFID and
keypad is a component
of the JABLOTRON 100 system. Its modular
architecture enables users to create a combination whose size of
installation perfectly meets their needs. The device should be installed
by a trained technician with a valid certificate issued by an authorised
distributor.
The wireless access module comprises the keypad (5), RFID
card / tag reader (5), LCD display (4) and the first control
segment (1). JA-192E segments can be used to extend the
JA-154E unit by the required number of segments (the max.
allowed amount is 20 on one unit). The keypad cover (7) can be
removed if the user prefers for full permanent access.
Figure: 1 – control segment; 2 – segment buttons; 3 – backlit activation
button; 4 – LCD display; 5 – access module with RFID card reader; 6 – tabs
for module opening; 7 – keypad cover screws
Figure: 8 – control segment connector; 9 – production code; 10 – terminals;
11 – mini USB connector; 12 – batteries; 13 – tamper contact
Installation
1. Press the four tabs (6) on the sides (see 1st figure) one by one
and release the keypad from the plastic base.
2. When installing more control segments, first remove the socket
cover on the 1
st
segment.
3. Remove the plastic windows from the segments (by levering on
both sides of the segment near the buttons).
4. Always connect the segment wires to the connector of the
previous segment and click them into each other (we recommend
coiling the wires by turning the segment by 360° - this will prevent
any possible damage to the wires between the plastic parts). Use
this method to install all the required control segments. Finally
push the socket cover in.
5. Insert four 1.5V alkaline AA batteries into the keypad.
6. Attach the base onto the selected place together with the
segments using screws. If multiple control segments are
required attach them onto the wall using screws as well (use
the number of screws required).
7. Connect the segment wires to the internal connector of the
keypad (8).
8. Insert the keypad into the base.
9. Proceed according to the control panel installation manual.
Basic procedure:
a. There must be a JA-110R radio module installed in the
control panel with a reliable communication range to the
keypad.
b. When batteries are inserted, the yellow LED starts to light
permanently which indicates that the keypad has not been
enrolled to the system yet.
c. Go to the F-Link software, select the required position in
the Devices window and launch enrollment mode by
clicking on the Enroll option.
d. Press the backlit activation button (3) – the keypad is thus
enrolled and the yellow LED indicator goes off. (This can
take a few sec.). An enrollment signal can also be sent by
inserting the batteries.
10. When you have completed installation, insert descriptive labels
behind the segment plastic windows and close them. Label
printing is a part of the F-Link software (Devices window, at the
keypad position – Internal settings), or you can use the label
printer.
Note:
Enrolling the module to the system is possible by entering the production
code (9) via F-Link software or by a production code reader. All digits under
the production code are required (1400-00-0000-0001).
To comply with the EN 50131-3 norm it is necessary to fix the cover tab by
the screws from the accessories. In picture no 1 the cover tabs are fixed by
the arrows.
C
l
i
c
k
!
ABCD...123
C
l
i
c
k
!
2
3
1
4
Figure: Insertion of a label into a control segment
Setting the properties
Go to the Devices window in the F-Link software. When you are at
the keypad position, use the Internal settings option. The particular
unit is displayed and it is possible to set its properties. It is possible to
assign the required functions to individual segments (controlling of
sections, section status signalling, alarm triggering, PG output
control, PG output status signalling, etc.). More details are available
in the F-Link software.
A common segment (up to 2 of them allowed on one keyboard)
simulates the simultaneous pressing of several segments which are
placed on this keyboard and which control sections. The selection of
sections which are assigned to the common segment is performed by
F-Link SW, the Devices window. At the keyboard position select
Internal settings / and Common segment 1 (2) and mark the segments
which will be operated en bloc. The selected sections will be set / unset
after pressing a button on the common segment. If the states of the
segments which are operated by the common segment are mixed, then
only the segments that need changing will be set / unset. If partial
setting is enabled for some segments, then the common segment
respects this: 1 st. press = partially setting, 2nd press = full setting. It is
not suitable to combine a common segment with a common section
The JA-154E wireless access module with LCD, RFID and keypad 1 / 2 MLU56205

Other manuals for jablotron JA-154E

Question and Answer IconNeed help?

Do you have a question about the jablotron JA-154E and is the answer not in the manual?

jablotron JA-154E Specifications

Power IconPower
battery typealkaline batteries AA (LR6)
battery voltage1.5 V
battery capacity2400 mAh
power input from external supply0.5 W
Communication IconCommunication
communication band868.1 MHz
communication range200 m
RFID frequency125 kHz
Operating Environment IconOperating Environment
operating temperature range-10 to +40 °C
operational environmentEN 50131-1 II. Indoor general
typical life time1 - 2 year(s)
Weight and Dimensions IconWeight and Dimensions
dimensions102 x 145 x 33 mm
weight350 g

Summary

Installation

Control Segment Wiring

Connect segment wires to the previous segment's connector and click together to prevent wire damage.

Segment Installation

Install all required control segments by turning them 360 degrees, then push the socket cover in.

Battery Installation

Insert four 1.5V alkaline AA batteries into the keypad for power.

Attaching Base and Segments

Attach the base with segments to the wall using screws.

Setting the Properties

F-Link Software Configuration

Configure keypad properties via the F-Link software's Devices window for segment control and signaling.

Common Segment Functionality

Simulate simultaneous segment pressing for sections via Common Segment 1 (2) in F-Link.

Module Operation and Power

Automatic Shutdown

Module conserves energy by shutting down optical indicators after 10 sec. of inactivity.

Alternative Power Source

Keypad can be powered by an external 12V DC supply, preventing sleep mode.

External Door Detector Input

Input terminal for an external door detector, which can wake the keypad upon detection.

Maintenance and Upgrades

Battery Replacement Procedure

Switch system to service mode before changing batteries to avoid tamper alarm.

Unit Modification

Modify segments by levering them out; use 'Upload' in F-Link for new JA-192E synchronization.

Firmware Upgrade Process

Upgrade firmware via F-Link software and miniUSB cable, performed by a service technician.

Technical Specifications

Power and Communication

Details on battery type, power input, communication band, and range.

Physical and Compliance Data

Specifications for dimensions, weight, RFID frequency, and compliance standards.