tionalchargingshouldbedoneonce everymonth.
Localtemperature
Specificgravityoffullychargedbattery
under15
Wheretemp-40 aboveinwinter 1.290 1260
Wheretemp-30 aboveinwinter 1280 1250
Wheretemp-20 aboveinwinter 1270 1240
Wheretemp0belowinwinter 1270 1240
Winter Summer
Wheretemp-40 belowinwinter 1.310 1.270
Table1Specificgravityofelectrolyte
Measuredtempofelectrolyte +45 +30 +15 0 -15 -30 -45
Correctedvalueonhydrometer +0.02 +0.01 0 -0.01 -0.02 -0.03 -0.04
Table2correctedspecificgravityvalueofelectrolyteunder15
68
OWNERSMANUALfor
HFC1061,HFC1063,HFC1083
seriestrucks
69
sensor
Fuellevelgaugesensor.
Thefuellevelsensoradoptssliding-
resistertype.Floatersriseanddrop
withtheoillevelchanging,which
causestheresistertoconnector
short-circuittomaketheelectromag
neticfuellevelgaugechange.Con
nectterminalofthefuellevelalarm
lampwiththeindicatorlighttoindi
catethelowestfuellevel.
Watertemperaturegaugesensor
Thetemperaturesensorisathermis
torthatismountedinwaterjacketto
indicatetemperatureofcoolingwater
anditmatcheswiththewatertem
peraturegaugeoninstrumentboard.
Thewatertemperaturesensorhasa
negativetemperaturecoefficientand
itsresistancedecreaseswiththein
creaseofwatertemperature,which
changecurrentgoingbyit.Don'tre
placethesensorwithapositivetem
peraturecoefficientone,orthewater
temperaturegaugewillnotworkcor
rectly.
Oilpressurealarm
Oilpressurealarmdeviceisanormal
closed switch. It will be opened
whenoilpressurereachesorover
thelowestpressure,sothatcircuitis
disconnectedandindicatorgoesout.