Diagnosis
Diagnosis
Diagnosis
Diagnosis and
and
and
and Test
Test
Test
Test
1. Fault diagnosis of Battery
Fault
Fault
Fault
Fault Fault
Fault
Fault
Fault symptoms
symptoms
symptoms
symptoms Cause
Cause
Cause
Cause analysis
analysis
analysis
analysis Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Excessive
shedding of
active material
Excessive sediments at the battery
bottom
Excessive low battery capacity
Perpetual red brown of cell wall and
operating bolt
Red brown electrolyte
The electrolyte is reddish and there
is pulpy shedding of pole plate
active materials, separators are in
softening state and negative pole
plate active materials are softening
expansion.
Massive shedding
Too high set valve of vehicle
circuit regulator
Too large current in charging and
too long charging time
Too large discharge capacity and
too long discharge time
High temperature and long service
time due to long-term vehicle
running
Unqualified pole plate
manufacture
Clean the sediments with
washing method and charge
it for reuse
Replace with a new battery
Reverse
installation of
polarities
For one reversed cell, 8V
For two reversed cells, 4V
For the whole reversed cells-12V
Manufacturing quality
Replace with a new battery
Disassemble and reinstall
Reverse charging
of polarities
The voltage is negative
The colors of positive and negative
terminal posts are reversed.
The colors of pole plates are
reversed.
Misconnection of positive and
negative polarities in charging
Discharge the capacity of
battery after its reverse
charging of polarities
completely
Charge the battery with
small current and then with
normal current in the case of
response of every cell
For serious cases, replace
with a new battery
Battery
explosion
Terminal post sparking
Broken positive circuit
Holes and cracks in battery case and
cover
Incorrect installation
Aged and thin circuit
Faulted operation of generator
Interference of external sparks
Insufficient solder for terminal
post
Broken busbar
Dropped plate
Broken intermediate terminal post
Broken pole plate
Firmly install
Replace the circuit
Eliminate generator fault
Keep the battery away from
heat source
Always keep vent
unblocked.
Replace with a new battery
Low capacity in
early stage
Underpowered start
Low voltage value
Slow response
Unfirm connection or circuit fault
It exceeds the storage period.
Positive pole plate passivation
Negative pole plate oxidation
Slightly leaky separator
Inspect the circuit carefully
Carry out boost charge