Instruction Manual
Air Conditioning Unit
Model: EX03018 / EX03019

Questions and Answers

Summary

Warning

Notes

Features and Components

Product Features

Lists key functionalities like cooling, dehumidification, fan modes, energy rating, and timer.

Component Identification

Diagram identifying major parts of the air conditioning unit including front, rear, and top components.

Installation and Adjustment

Heat Pipe Assembly Installation

Instructions for screwing the heat pipe assembly into the exhaust port on the rear panel.

Window Sealing Plate Installation

Steps to install and adjust the window sealing plate assembly for exhaust hose placement.

Unit Body Installation

Procedure for positioning the unit body with the installed heat pipe, ensuring adequate clearance.

Control Panel Setting

Control Panel Overview

Details the buttons and display of the air conditioning unit's control panel for operation.

Operating Instructions of the Remote Control

Remote Control Operation

Explains the function of each button on the remote control for managing modes, temperature, and timer.

A Variety of Protection Functions

Frost Protection

Describes the automatic protection status when exhaust pipe temperature is too low.

Overflow Protection

Details the alarm and indicator for water pan overflow and the required drainage procedure.

Automatic Defrosting

Notes the availability of an automatic defrosting function for cooling models.

Compressor Protection

Explains the 3-minute delay booting protection for compressor longevity.

Drainage Instructions

Manual Drainage

Step-by-step guide for draining water manually when the water pan is full.

Continuous Drainage

Instructions for optional continuous water drainage in cooling and dehumidifying modes.

Maintenance

Surface Cleaning

Guidelines for cleaning the unit's surface with a damp cloth, avoiding chemicals.

Filter Screen Cleaning

Procedure for cleaning the filter screen to maintain air conditioning effectiveness.

Unit Storage

Steps for preparing and storing the unit properly in a dry place.

Troubleshooting

Appendix

Schematic Diagram

Presents a schematic diagram of the air conditioning system components.

Overview

This document is an instruction manual for a Jack Stonehouse Air Conditioning Unit, models EX03018 and EX03019. It provides detailed information on the unit's features, components, installation, operation, protection functions, drainage, maintenance, and troubleshooting.

Function Description

The air conditioning unit offers multiple functions:

  • Cooling: Provides cooling for indoor spaces.
  • Dehumidification: Reduces humidity in the air.
  • Fan: Operates as a fan for air circulation.
  • Sleep Mode: Offers a quiet setting for nighttime use.
  • 24-hour Timer: Allows scheduling of operation.

Important Technical Specifications

While specific numerical technical parameters are stated to be on the product's nameplate, the manual provides several important operational and safety specifications:

  • Refrigerant: The unit uses refrigerants, and users are warned that they may not contain an odor. Servicing of the refrigerant circuit requires a valid, industry-accredited certificate.
  • Room Area: The appliance must be installed, operated, and stored in a room with a floor area larger than 12m².
  • Exhaust Hose Length: The length of the exhaust hose should be between 280mm and 1,500mm. Using extension tubes or different hoses is not recommended as it may cause malfunction or overheating.
  • Temperature Range: For optimal use, the machine is recommended to operate at an ambient temperature of 7-35°C (44-95°F) in cooling mode.
  • Compressor Protection: Features a 3-minute delay booting protection function to increase the service life of the compressor.
  • Frost Protection: Automatically enters protection status if the exhaust pipe temperature is too low in cooling, dehumidifying, or economic power saving modes.
  • Overflow Protection: An alarm sounds and the "FULL" indicator light flashes when water in the water pan exceeds the warning level, requiring manual drainage.
  • Automatic Defrosting: Cooling models have an automatic defrosting function.

Usage Features

The air conditioning unit is designed for ease of use and mobility:

  • Compact Design: Facilitates placement in various indoor settings.
  • Castor Wheels: Equipped with omni-directional wheels for easy movement.
  • LED Display Control Panel: Provides a clear interface for operation.
  • Remote Control: Allows convenient operation from a distance. The remote control includes keys for power, mode selection (cooling, fan, dehumidifying), temperature/timing adjustment (up/down), fan speed selection (high, medium, low), timer setting, and louver swing control. It also has a C-F key to switch between Celsius and Fahrenheit.
  • Installation: The unit is easily moved and installed. It requires a minimum distance of 50cm from surrounding objects or walls. The heat pipe assembly screws into the exhaust port on the rear panel, and the window sealing plate assembly can be mounted horizontally or vertically to accommodate the exhaust pipe.
  • Drainage: Supports both manual drainage when the water pan is full and continuous drainage (optional, for cooling and dehumidifying modes) by connecting a drainage pipe to a bucket.
  • Safety Warnings: Users are advised not to accelerate defrosting or clean with unapproved means, not to pierce or burn the unit, keep ventilation openings clear, and avoid placing objects in air inlets/outlets. It should not be used in bathrooms or humid environments, and should be kept away from flammable substances and heat sources. Children aged 8 and above, and persons with reduced capabilities, can use the appliance under supervision.

Maintenance Features

Regular maintenance is crucial for the unit's performance and longevity:

  • Surface Cleaning: The surface should be cleaned with a damp soft cloth. Chemical solvents like benzene, alcohol, or gasoline should not be used to avoid damage.
  • Filter Screen Cleaning: The filter screen should be cleaned once every two weeks to prevent dust clogging and maintain effectiveness. This involves unscrewing four screws to remove the EVA filter screen and rear housing, then rinsing the filter screen in warm water with neutral detergent and allowing it to dry.
  • Unit Storage: For storage, the unit should be drained completely, run in low-wind ventilation mode until the drainage pipe is dry to prevent mildew, unplugged, and the power cord wrapped. The exhaust pipe should be removed and stored properly. The unit should then be covered with a plastic bag and stored in a dry place, out of reach of children, with dust control measures.
  • Remote Control Battery: Batteries of the remote control should be removed for proper storage.
  • Troubleshooting: The manual includes a troubleshooting guide for common issues like no power, "FL" display (overflow), poor cooling, noise, remote control malfunction, and error codes 'E1' (room temperature sensor abnormal) and 'E2' (pipe temperature sensor abnormal), providing solutions or recommending professional service.