PROBABLE CAUSE REMEDYPROBLEM
19
TROUBLESHOOTING GUIDE
F. Improper or defective wiring.
G. High temperature safety
switches tripped.
H. Subnormal voltage.
I. Locked shaft or impeller.
J. Motor windings burned out.
K. Defective starting switch
inside motor.
F. *
G. Reset buttons on heater after
water has cooled; see *Note
if switches continue to trip.
H. Call an electrician or your
power company.
I. *
J. *
K. *
10. Motor will not start.
(Continued)
11. Motor stops.
A. Motor overload condition.
B. Selector switch failure.
C. Relay failure.
D. Inadequate supply wiring.
E. High temperature safety
switches tripped.
A. Let cool for one hour.
Motor overload protector will reset;
if problem persists, see *Note.
B. *
C. *
D. Consult electrician to cor-
rect wiring to unit.
E. Reset buttons on heater after
water has cooled; see *Note
if switches continue to trip.
12. Air Blower does not operate.
A. Power off.
B. ACC switch in OFF.
C. House circuit breaker
tripped, no power to
system.
D. ELCB tripped.
E. Faulty motor.
A. Turn on power at service
panel.
B. Select other function.
C. Reset circuit breaker.
D. Reset ELCB.
E. *
*Note: The skills and tools necessary for the safe repair of this spa require the services