STEP 5: When you finished changing the Function setting, slide SET
Switch to the original side. The screen will show END.
◎ General Functions
F000
Decimal Point Adjustment
0 No Decimal 1234567
1 1 Decimal 123456.7
2 2 Decimal 12345.67
●
3 3 Decimal 1234.567
4 4 Decimal 123.4567
F001
Weighing Unit Selection
0 None
●
1 Kilogram
2 Pound
F002
Display Update Rate
10 10 Times/Sec
●
20 20 Times/Sec
40 40 Times/Sec
F003
Digital Filter
Filter
Environmental
Vibration
Response
Speed
0 No stage Weak Bad Fast
1 1
st
stage
2 2ed stage
3 3
rd
stage
▲ ▲ ▲
●
4 4
th
stage
▼ ▼ ▼
5 5
th
stage
6 6
th
stage
7 7
th
stage Strong Good Slow
F004
Set ZERO Range
5
±5% of weighing platform Full Capacity
●
10
±10% of weighing platform Full Capacity
20
±20% of weighing platform Full Capacity
30
±30% of weighing platform Full Capacity