JIF-2002 WEIGHING INDICATOR&CONTROLLER
43
STEP 3: The screen will show SP1, please press the ↵ key. The screen
will show a 6-digit value with blinking 0 000.000. Please use
the or key to change position and the or key to
change value. Please press the ↵ key to confirm SP1 value.
STEP 4: The screen will show SP2, please press the ↵ key. The screen
will show 6-digit value with blinking 0 000.000. Please use the
or key to change position and the or key to
change value. Please press the ↵ key to confirm SP2 value.
STEP 5 : The screen will show Free, please press the ↵ key. The screen
will show 6-digit value with blinking 0 000.000. Please use the
or key to change position and the or key to
change value. Please press the ↵ key to confirm Free Fall
value.
STEP 6: The screen will show Hi, please press the ↵ key. The screen
will show 6-digit value with blinking 0 000.000. Please use the
or key to change position and the or key to
change value. Please press the ↵ key to confirm Hi (Over
Limit) value.
STEP 7 : The screen will show Lo, please press the ↵ key. The screen
will show 6-digit value with blinking 0 000.000. Please use the
or key to change position and the or key to
change value. Please press the ↵ key to confirm Lo (Under
Limit) value.
STEP 8: The screen will show CODE 00, please press the STANDBY
key to leave set point codes. If you wish to continue reset other
SET POINT CODES. Please enter values according to step1 to
step 8 again.