Do you have a question about the J&E Hall JCC2 and is the answer not in the manual?
Lists the standard features and specifications of the JCC2 cellar cooler units.
Provides cooling capacities in kW for various ambient temperatures across different models.
Details system pipe sizes, maximum pipe run, unit airflows, indoor airthrow, and noise levels.
Presents the physical dimensions and weights for indoor and outdoor units across different models.
Outlines electrical specifications including power supply, fuse ratings, and cable requirements.
Provides essential safety notes and guidelines for installation, maintenance, and handling of the equipment.
Advises on selecting optimal installation locations for both indoor and outdoor units to ensure performance and maintenance access.
Specifies required clearance distances around indoor and outdoor units for proper airflow and maintenance.
Details guidelines for installing refrigerant piping, including material, route, and brazing practices.
Describes the procedure for pressure testing the system using nitrogen to detect leaks before evacuation.
Explains the process of evacuating the system to remove air/moisture and charging with refrigerant.
Details the fitting of the evaporator drain pan and the recommended drain pipe size and material.
Covers electrical supply requirements, cable routing, and connection procedures for indoor and outdoor units.
Outlines the steps for commissioning the system, including checks, temperature settings, and final tests.
Provides a checklist for routine inspection of units, including leaks, mountings, and electrical connections.
Details maintenance for fan motors and blades, emphasizing cleaning and checking for issues.
Instructs on cleaning condenser and evaporator coils, warning against high-pressure washers.
Advises checking controller settings and temperature probe calibration for proper operation.
Recommends inspecting power supply, checking running current, voltage, and wiring connections.
Outlines how to check refrigerant charge and perform a leak test for system integrity.
Guides on the proper procedures for decommissioning and disposing of the unit and its components as hazardous waste.
Explains updated F-Gas regulations regarding leak testing frequency based on refrigerant charge.
Shows detailed dimensional drawings for the JCC2-25E and JCC2-40E indoor unit models.
Presents dimensional drawings for the JCC2-50E and JCC2-60E indoor unit models.
Provides dimensional data and diagrams for the outdoor units (J5LC models).
Includes wiring diagrams for indoor (pre/post March 2015) and outdoor units.
Explains how to operate the Dixell XR02CX electronic controller, including setting temperatures and defrost.
Lists and defines parameters for the Dixell XR02CX controller, including ranges and default settings.
Details the installation and connection of an optional fan speed controller for longer pipe runs.
Contains the manufacturer's declaration of conformity with relevant directives and standards.
| Category | Accessories |
|---|---|
| Refrigerant | R404A |
| Model | JCC2 |
| Manufacturer | J&E Hall |
| Application | Commercial Refrigeration |
| Frequency | 50Hz |
| Power Source | Electric |