Page 7
ENGLISH
WARNING
A terminal bar marked “GROUND” is provided within the power center.
To reduce the risk of electrical shock, connect this terminal bar to
the grounding terminal of your electric service or supply panel with a
continuous copper conductor having green insulation and one that is
equivalent in size to the circuit conductors supplying this equipment, but no
smaller than no. 12 AWG (3.3mm
2
). In addition, a second wire connector
should be bonded with a no. 8 AWG (8.4mm
2
) copper wire to any metal
ladders, water pipes, or other metal within ve (5) feet (1.52m) of the pool/
spa. In Canada, the bonding wire must be minimum 6 AWG (13,3mm
2
).
WARNING
A ground-fault circuit-interrupter must be provided if this device is used
to control underwater lighting xtures. The conductors on the load side
of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or
enclosures containing other conductors unless the additional conductors
are also protected by a ground-fault circuit-interrupter. Refer to local codes
for complete details.
Attention installer: Install to provide drainage of
compartment for electrical components.
SAVE THESE INSTRUCTIONS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy Pro Series AquaLink RS OneTouch Control Systems and is the answer not in the manual?

Jandy Pro Series AquaLink RS OneTouch Control Systems Specifications

General IconGeneral
BrandJandy Pro Series
ModelAquaLink RS OneTouch Control Systems
CategoryControl Systems
LanguageEnglish