Installation
+ Note:
+ 2D detectors require 2D Pana40 Plus Controller
+ 3D detectors require 3D Pana40 Plus Controller
Pana40Plus 2D / 3D Controllers
Installation Guide
Ref. No. 843 852GB Version 1
Set-up for 3D model controllers
To congure 3D Pana40 Plus Controller:
+ Fit the Pana40 Plus 3D detectors (Models 77X) to the
controller.
+ All 3D controllers are factory set as: 3D activated settings
‘as door close’ on ‘Highest’ sensitivity’.
+ Select the 3D Operating Mode using switches 1 & 2 if
necessary (see Table 1 opposite)
+ Adjust the 3D Sensitivity using switches 3 & 4 if
necessary (see Table 1)
3D Operating Mode Switch 1 Switch 2
As Doors Close OFF OFF
At 2’8” (800mm) OFF ON
3D timeout - 20 seconds ON OFF
3D timeout - 10 seconds ON ON
3D Sensitivity Switch 3 Switch 4
Highest ON ON
Intermediate OFF ON
Normal ON OFF
O OFF OFF
Table 1
1. Secure Pana40 Plus Controller in a suitable position on
top of car to avoid damage.
2. Connect the Controller with the correct mains supply
voltage and Inputs (see instruction label inside lid).
3. It is important to ensure that the detector cables and
travelling cables (015 199) are secured to the door
correctly and that the travelling cable is routed to the
controller correctly.
4. Connect the Transmit (TX) and Receive (RX) leads into
the Controller sockets as marked
5. On completion, carefully open & shut doors by hand to
check the travelling cable (015 199) has a smooth free
movement and is not liable to snag on anything during
normal operation otherwise there is a risk of leads being
damaged by the lift doors or caught up when lift moves.
6. Correct operation will show display showing 3 bars
scanning up/down. If this is not observed, switch
number SW3 ON and check trouble shooting guide, card
is located on the side of the controller lid.
7. Static Installation Jumper J1 needs to be over both pins
(See instruction label inside lid).