EasyManua.ls Logo

jbc T210 Series - Cartridge Changing Procedures; T210 & T245 Cartridge Changing; T470 Cartridge Changing

jbc T210 Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mark
*Important
It is essential to insert the cartridges as far as the mark for a proper connection.
T210 & T245 Changing cartridges
1. Removing 2. Inserting 3. Adjusting
Place the handle in the
extractor and pull to remove
the cartridge.
Place the handle on top of
the new cartridge and press
down.
Use the holes for fixing the
cartridge* as follows:
A. For straight C210.
B. For curved C210.
C. For curved C245.
D. For straight C245.
B
C
A
D
Save time and change cartridges safely without switching the station off.
Loosen the screw. Place the Soldering Iron in
the extractor and remove the cartridge.
T470 Changing cartridges
1. Removing 2. Inserting
Loosen
Insert the new cartridge* and press slightly
as far as the mark and tighten the screw.
www.jbctools.com
5