Jelight UVO-CLEANER - User Manual

Jelight UVO-CLEANER
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Jelight Company, Inc.
2 Mason
Irvine, CA 92618 U.S.A
Tel: +1(949) 380-8774 Fax +1(949) 768-9457
UVO-CLEANER
Model 18, 24, 30
Instruction Manual
Original Instructions REV. E
®

Questions and Answers

  • M
    Marc FieldsAug 3, 2025
    How to troubleshoot a Jelight UVO-CLEANER Laboratory Equipment system with no power?
    • A
      Alison RobertsAug 3, 2025
      If your Jelight Laboratory Equipment system isn't powering on, try the following: First, twist the Emergency Stop Button clockwise to reset it. Then, check that the AC Power Cord is undamaged and properly plugged into a working Socket Outlet. After that, inspect the Fuse on the rear panel. Finally, check or reset the main Circuit Breaker for the Socket Outlet.
  • D
    Diana DavisAug 8, 2025
    What to do if ozone is present outside of the Jelight UVO-CLEANER system during operation?
    • B
      bartonshelbyAug 9, 2025
      If you detect ozone outside the Jelight Laboratory Equipment system during operation, take these steps: * Ensure the Exhaust connections are tight. * If the Media Inlet Port is connected to a pressurized gas supply, reduce pressure/flow. * If using the optional Ozone Filter & Blower assembly: * Check the Blower is operating. * Check the Blower Plug is connected to the Socket Outlet (Blower) at the rear of the machine. * Make sure the Ozone Filter is connected in the upright position. * Check the O-ring between the Ozone Filter and Blower is sealing correctly. * Check the Lid is closed properly; the Lid latch may require adjustment.
  • D
    Dr. Dorothy LewisAug 15, 2025
    Why is the intensity measurement below normal on my Jelight UVO-CLEANER?
    • N
      Natalie JohnsonAug 15, 2025
      If the intensity measurement is lower than expected on your Jelight Laboratory Equipment, consider the following potential causes and solutions: * Replace the UV Lamp Assembly. * Ensure the distance between the lamp and detector is within .12”-.20” [3 - 5mm]. * The radiometer/detector may require recalibration; a calibration period of 3–4 months is recommended when subjected to strong UV radiation. * If solarization occurs, the detector will require replacement.
  • T
    Tammy Hogan DDSAug 20, 2025
    What to do if the Jelight UVO-CLEANER Laboratory Equipment system has power but the Timer and Lamp do not operate?
    • J
      Joe HillAug 20, 2025
      If your Jelight Laboratory Equipment system has power, but the Timer and Lamp aren't working, check that the Lid is closed properly. The Lid Switch Actuator must activate two safety interlock switches before the Timer will operate.
  • S
    Stephanie HughesAug 27, 2025
    How to fix a Jelight UVO-CLEANER Laboratory Equipment when the Lamp Indicator does not light up?
    • K
      Kari LoveAug 27, 2025
      If the Lamp Indicator on your Jelight Laboratory Equipment isn't lighting up, first check that the Power-On Indicator lamp is on. Also, inspect the UV Lamp Assembly for any breaks, cracks, or other damage.

Summary

Safety Guide

Hazardous Voltage Warning

Caution against accessing internal components while power is connected due to high voltage.

Ozone Inhalation Hazard

Warning about ozone production and the need for ventilation; instructions to switch off if detected.

Ultraviolet Light Hazard

Alerts to harmful UV radiation from the lamp and the need for eye and skin protection.

Introduction to UVO-Cleaner

UVO Cleaning Method Explained

Details the photosensitized oxidation process using UV radiation and atomic oxygen.

Key Applications

Lists various industries and processes where the UVO-Cleaner® is used effectively.

Specifications

Machine Description

Front Panel Overview

Details the controls, indicators, and buttons on the front of the unit.

Rear Panel Connections

Identifies ports for power, exhaust, media input, and other rear-mounted features.

Interior Layout

Illustrates internal components such as the lamp assembly, tray, and height adjustment mechanism.

Parts Assembly

System Setup

Lamp Installation

System Operation

Scheduled Maintenance

Intensity Measurement

Procedure and Setup

Steps for preparing the unit and detector for intensity measurement, including tray height adjustment.

Performing the Measurement

Instructions on operating the radiometer and recording the UV intensity readings.

Troubleshooting

Limited Warranty

Product Information and Disclaimer

Warranty Registration Form

Jelight UVO-CLEANER Specifications

General IconGeneral
BrandJelight
ModelUVO-CLEANER
CategoryLaboratory Equipment
LanguageEnglish