19
You can set an option on one fixture by sending a unicast RDM command to that
one fixture only, or you can set the same option on all the fixtures on the data link
by sending a broadcast RDM command to all the devices on the link.
For status reading, you can only use unicast RDM to read information from an
individual fixture.
RDM functions
As a minimum, the fixture supports the following RDM functions:
Device discovery
DISC_UNIQUE_BRANCH
DISC_MUTE
DISC_UN_MUTE
Device management
GET SET
DEVICE_INFO
9
IDENTIFY_DEVICE
9 9
DMX_START_ADDRESS
9 9
SOFTWARE_VERSION_LABEL
9
SUPPORTED_PARAMETERS
9
PARAMETER_DESCRIPTION
9
COMMS_STATUS
9
QUEUED_MESSAGE
9
STATUS_MESSAGES
9
DEVICE_MODEL_DESCRIPTION
9
MANUFACTURER_LABEL
9
DEVICE_LABEL
9 9
FACTORY_DEFAULTS
9
DMX_PERSONALITY
9 9
DMX_PERSONALITY_DESCRIPTION
9
DEVICE_HOURS
9
BOOT_SOFTWARE_VERSION_ID
9
BOOT_SOFTWARE_VERSION_LABEL
9
SLOT_DESCRIPTION
9 9
RESET_DEVICE
9