1. Minimum 32” drain loop, 1/2” inside diameter minimum. Floor drains require a siphon break.
2. Connections preferably located toward left side of dishwasher. Care should be taken to route plumbing
away from motor and blower (if equipped).
3. Electrical and plumbing should meet all local and national codes.
4. Electrical and water supplies should enter cabinet opening on the floor, or through the back or side walls,
as shown in the shaded area of the drawing.
5. When installing dishwasher in or near a corner, allow enough room for door to open without interfering
with cabinet drawers or hardware.
Electrical requirements: Adequately wired individual 120V A/C, 60Hz approved electrical circuit. Use
required fuse (15 amp) or comparable circuit breaker.
NOTES:
Style of product may vary from picture
Keep back
free of drain
inlet water and
electrical.
Preferred
drain area
Preferred
drain area
A
D
C
B
Preferred
drain area
PRODUCT DIMENSIONS
INCHES
MODEL SKUs
A
B
C
D
24 7/8
20 1/4
23 7/8
33 3/4-35 1/4
JDB1105AWW
JDB1105AWB
JDB1105AWS
Important:Because of continuing product improvements, Jenn-Air reserves the right to change specifications without notice. Dimensional specifications are provided for
planning purposes only. For complete details see installation instructions that accompany each product before selecting cabinetry, making cutouts or beginning installation.
Question and Answer IconNeed help?

Do you have a question about the Jenn-Air JDB1105AW and is the answer not in the manual?

Jenn-Air JDB1105AW Specifications

General IconGeneral
TypeBuilt-In
Drying SystemHeated Dry
Control TypeElectronic
Place Settings12
Energy Star CertifiedYes
Third RackNo
Stainless Steel TubYes
Soil SensorYes
Delay StartYes
Width24 inches

Summary

Product Dimensions and Models

Dimension A

Width of the dishwasher, 24 7/8 inches.

Dimension B

Depth of the dishwasher, 20 1/4 inches.

Dimension C

Cabinet opening width, 23 7/8 inches.

Dimension D

Height range, 33 3/4 to 35 1/4 inches.

Model SKUs

Available model identifiers: JDB1105AWW, JDB1105AWB, JDB1105AWS.

Installation Notes and Requirements

Drain Loop and Floor Drains

Minimum 32" drain loop, 1/2" diameter. Floor drains require a siphon break.

Plumbing and Electrical Connections

Preferably left side, route away from motor/blower. Meet local/national codes.

Electrical and Water Supply Entry

Supplies should enter cabinet opening on the floor or through back/side walls.

Corner Installation Clearance

Allow enough room for door to open without interfering with cabinet drawers or hardware.

Electrical Requirements

Use adequately wired 120V A/C, 60Hz circuit with 15 amp fuse/breaker.