TIMER AND SOLENOID REPLACEMENT
WATER INLET VALVE (SOLENOID)
The water inlet valve is open during the fill and rinse cycles. The machine fills through the rinse arms.
Check the exploded view for model you are servicing to determinate the location of the water inlet valve.
This valve cannot be serviced and must be replaced if defective.
NOTE: If you are replacing the water inlet valve on a model F-22 or 747 (door type machines), the filter screen
must be removed to provide the required increased water flow.
CYCLE TIMER
JET-TECH washers use a mechanical type timer which cannot be serviced and must be replaced if defective