TIMER AND SOLENOID REPLACEMENT
WATER INLET VALVE (SOLENOID)
• The water inlet valve is open during the fill and rinse cycles. The machine fills through the rinse arms.
• Check the exploded view for model you are servicing to determinate the location of the water inlet valve.
• This valve cannot be serviced and must be replaced if defective.
NOTE: If you are replacing the water inlet valve on a model F-22 or 747 (door type machines), the filter screen
must be removed to provide the required increased water flow.
CYCLE TIMER
• JET-TECH washers use a mechanical type timer which cannot be serviced and must be replaced if defective