Problem Check Y/N Action Picture
STEP 3
Machine LED lights
are on, blue Charge
Buttons are on but
Machine does not
produce Dry Ice
Does the Cylinder have
Eductor / Siphon /Dip
Tube to be able to
withdraw liquid?
No Order a Cylinder with
Eductor / Siphon /Dip Tube
Yes Next check
Is the Cylinder full? No Try another Cylinder that is
full or order a new full
Cylinder
Yes Next check
Is your Hose O Ring in
place?
No Use 0.16” Allen Key and
replacement Rubber O Ring
provided to replace O Ring
If no O Rings left contact
JetChill
Yes Contact JetChill as Machine
may need to be returned to
factory to clean Solenoid
Problem Check Y/N Action Picture
STEP 4
Machine does not
produce full Dry
Ice charge in Glass
Are Jets clean? No Detach Cylinder and mains
plug and unscrew Probe Cap
(11)
Remove Delivery Pipe (8) and
unscrew Jet (10)
Clean inside Jet (10) and Jet
Plug (9) with compressed air
Once Jet is clean reassemble
Probe
Yes Next check
Is charge time
sufficient?
No Detach Cylinder and mains
plug and unscrew Timer
Control Panel Cover
Turn screw driver (1.2mm)
anti clock wise to increase
Norm or Boost charge time
Switch
LED's to Static or Flash
as desired
Replace Panel Cover
Yes Contact JetChill as Machine
may need to be returned to
factory to clean Solenoid