EasyManua.ls Logo

Jeulin CL 3020 - User Manual

Default Icon
20 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Mesures et instrumentation
Measurement and instrumentation
Ref :
291 175
Français p 1
English p 10
Version : 9106
Multimètre CL 3020
CL 3020 multimeter
Question and Answer IconNeed help?

Do you have a question about the Jeulin CL 3020 and is the answer not in the manual?

Summary

Safety Related Information

Device Characteristics

DC Voltage Measurement

DC Voltage Ranges

Specifies the measurement ranges for DC voltage from 400mV to 1000V.

DC Voltage Resolution

Details the minimum measurable unit for DC voltage, which is 100µV.

DC Voltage Accuracy

Provides accuracy specifications for DC voltage measurements.

DC Voltage Input Impedance

States the input impedance for DC voltage measurements as 10 MΩ.

DC Voltage Overload Protection

Defines the overload protection limits for DC voltage measurements.

AC Voltage Measurement

AC Voltage Ranges

Specifies the measurement ranges for AC voltage from 400mV to 750V.

AC Voltage Resolution

Details the minimum measurable unit for AC voltage, which is 100µV.

AC Voltage Accuracy

Provides accuracy specifications for AC voltage measurements.

AC Voltage Input Impedance

States the input impedance for AC voltage measurements as 10 MΩ.

AC Voltage Overload Protection

Defines the overload protection limits for AC voltage measurements.

DC Current Measurement

DC Current Ranges

Specifies the measurement ranges for DC current from 400µA to 20A.

DC Current Accuracy

Provides accuracy specifications for DC current measurements.

DC Current Input Protection

Details input protection for DC current measurements, including fuse specifications.

AC Current Measurement

AC Current Ranges

Specifies the measurement ranges for AC current from 400µA to 20A.

AC Current Accuracy

Provides accuracy specifications for AC current measurements.

AC Current Input Protection

Details input protection for AC current measurements, including fuse specifications.

Resistance Measurement

Resistance Ranges

Specifies the measurement ranges for resistance from 400Ω to 400MΩ.

Resistance Accuracy

Provides accuracy specifications for resistance measurements across various ranges.

Resistance Open Circuit Voltage

Specifies the open circuit voltage for resistance measurements.

Resistance Overload Protection

Defines the overload protection limits for resistance measurements.

Continuity Test

Continuity Audible Signal

Describes the audible signal for continuity when resistance is below a threshold.

Continuity Overload Protection

Defines the overload protection limits for continuity testing.

Diode Test

Diode Test Current

Specifies the test current used for diode testing.

Diode Test Accuracy

Provides accuracy specifications for diode testing.

Diode Test Open Circuit Voltage

Specifies the open circuit voltage for diode testing.

Diode Test Overload Protection

Defines the overload protection limits for diode testing.

Capacitance Measurement

Capacitance Ranges

Specifies the measurement ranges for capacitance from 4nF to 400µF.

Capacitance Accuracy

Provides accuracy specifications for capacitance measurements across various ranges.

Inductance Measurement

Inductance Ranges

Specifies the measurement ranges for inductance from 4mH to 40H.

Inductance Accuracy

Provides accuracy specifications for inductance measurements across various ranges.

Inductance Test Frequency

Details the test frequencies used for inductance measurements depending on the range.

Frequency Measurement

Frequency Ranges

Specifies the measurement ranges for frequency from 4kHz to 4000kHz.

Frequency Accuracy

Provides accuracy specifications for frequency measurements.

Frequency Sensitivity

Details the minimum sensitivity required for frequency measurements.

Frequency Overload Protection

Defines the overload protection limits for frequency measurements.

Logic Test

Logic Test Threshold

Specifies the voltage thresholds for high and low logic levels.

Logic Test Indication

Describes the buzzer indication for low logic levels.

Logic Test Frequency Response

Details the frequency response for logic level detection.

Logic Test Detectable Pulse Width

Specifies the minimum detectable pulse width for logic signals.

Logic Test Pulse Limits

Defines the duty cycle limits for pulse detection in logic testing.

Logic Test Overload Protection

Defines the overload protection limits for logic testing.

Temperature Measurement

Temperature Ranges

Specifies the measurement ranges for temperature from -20°C to +750°C.

Temperature Resolution

Details the resolution for temperature measurements, which is 1°C.

Temperature Accuracy

Provides accuracy specifications for temperature measurements at different ranges.

Operation Guide

Maximum Value Retention

Explains how to activate and use the function to retain the maximum measured value.

Capacitance and Inductance Measurement

Provides step-by-step instructions for measuring capacitance and inductance.

Voltage Measurement Procedure

Details the procedure for performing voltage measurements, including probe connections.

Current Measurement Procedure

Guides on how to perform current measurements, including probe connections.

Measurement Procedures

Resistance and Continuity Measurement

Outlines the steps for measuring resistance and continuity.

Diode Test Procedure

Details the procedure for conducting a diode test, including probe reversal.

Frequency Measurement

Provides instructions for measuring frequency using the device.

Advanced Measurements

Capacitance Measurement Guide

Explains the procedure for measuring capacitance using the Cx socket.

Logic Level Measurement

Details how to perform logic measurements and interpret the display symbols.

Temperature Measurement Guide

Provides instructions for measuring temperature using a K-type thermocouple.

Maintenance and Service

Replacing the Battery

Instructions on how to replace the device's 9-volt battery.

Replacing the Fuses

Guides on how to access and replace the internal fuses (F1 and F2).

After-Sales Service Information

Details warranty, contact information, and procedures for repairs or spare parts.

Technical Support

Direct Technical Assistance

Information on expert availability and contact methods for technical support.

Online Assistance

Provides the web address for online assistance and FAQs.

Company Contact Details

Lists addresses and phone numbers for Jeulin's technical support in France and internationally.

Jeulin CL 3020 Specifications

General IconGeneral
BrandJeulin
ModelCL 3020
CategoryMultimeter
LanguageEnglish