MMAINTENANCE AND INSTRUCTION MANUAL - 3
English
TABLE OF CONTENTS
1. SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .03
2. MAIN COMPONENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .04
3. INTRODUCTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .05
4 GENERAL DESCRIPTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .05
4.1. Operation.
5. SYSTEM SETUP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .06
5.1. Installation recommendations.
5.2. Power supply connection.
5.3. Starting up.
6. INDICATIONS FOR END USERS
. . . . . . . . . . . . . . . . . . . . . .08
7. MAINTENANCE OPERATIONS
. . . . . . . . . . . . . . . . . . . . . . . . .09
7.1. Cleaning.
7.2. Troubleshooting guide.
7.3. Motor disassembly and extraction.
7.4.
Replacement/cleaning of non-return valve.
8. TECHNICAL SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . .12
9. LAYOUT AND SECONDARY VENTILATION
SYSTEM DIAGRAM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
10. EXPLODED VIEWS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
10.1. Lifting station assembly.
10.2. Caset assembly.
11. BASIC INFORMATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
12. EC DECLARATION OF CONFORMITY
. . . . . . . . . . . . . . .16
.
1. SAFETY INSTRUCTIONS
In order to reduce the risk of
electric shock, do not open the
top covers. Do not handle the
interior of the macerator; always
refer servicing to qualified
personnel.
In order to reduce the risk of fire
or electric shock, do not expose
this appliance to rain or flooding.
DETAILED SAFETY INSTRUCTIONS.
Please read all the safety and operating
instructions before using the appliance. Keep
them for future reference.
All the user safety indications, instructions and
operations included in this manual must be
observed.
LIFTING STATION
EB-705
MMAINTENANCE
AND INSTRUCTION
MANUAL
1en
English

Questions and Answers

  • J
    Jill RojasAug 17, 2025
    What to do if the JIMTEN Plumbing Product lifting station does not start?
    • T
      tracey99Aug 17, 2025
      If the lifting station doesn't start, it could be due to a few reasons. First, ensure the appliance is correctly connected. Next, verify that the electricity supply is correct. Lastly, if the electrical protection has been activated, wait about 20 minutes for the motor to cool down.
  • E
    Erin PattersonAug 20, 2025
    Why does my JIMTEN Plumbing Product motor work but not discharge properly?
    • J
      Justin MclaughlinAug 20, 2025
      If the motor is running but not discharging or doing so slowly, there may be a blockage in the drainage pipe. Try cleaning the drainage pipe to resolve this issue.
  • V
    Veronica MosesAug 22, 2025
    What to do if my JIMTEN Plumbing Product motor does not stop?
    • L
      laura02Aug 22, 2025
      If the motor doesn't stop, several factors could be the cause. Consider whether the drainage pipe has excess height or length, or if there's a loss of power due to too many elbows. Additionally, check for a blockage in the discharge pipe or obstruction due to limescale. Clean the discharge pipe or carry out the descaling process. If none of these actions solve the problem, it may be caused by a malfunction of the microswitch, and you should contact Technical Assistance.
  • B
    Brandon HarperAug 25, 2025
    What to do if the differential switch trips on my JIMTEN Plumbing Product?
    • D
      Don BrownAug 26, 2025
      If the differential switch trips, it is most likely because the motor’s earth connection is defective. As the motor is broken you should contact Technical Assistance.
  • J
    jeremiah92Aug 28, 2025
    Why does the JIMTEN Plumbing Product shower basin not drain well?
    • S
      Sara OrrAug 28, 2025
      If the shower basin doesn't drain well, it could be due to a possible obstruction of the drain. Try cleaning the drainage piping. Also, if the shower basin drain is siphonic, it might be creating plunging of air during drainage; in this case, remove the siphon from the shower basin valve.
  • D
    David CooperAug 31, 2025
    What to do if the JIMTEN Plumbing Product motor buzzes but doesn't turn?
    • K
      Karen WelchAug 31, 2025
      If the motor buzzes but doesn't turn, the turbine may be blocked by foreign matter. You should see maintenance operations (disassembly and extraction of the motor, page 11).
  • E
    Erin OrtizSep 2, 2025
    What causes strange noises from my JIMTEN Plumbing Product motor?
    • M
      Ms. Barbara Donaldson DVMSep 2, 2025
      A strange noise when the motor is working is usually caused by an obstruction or blockage from foreign matter that has fallen into the unit. Extract the matter from inside the unit. (See motor disassembly and extraction 7.3).
  • J
    jacqueline77Sep 5, 2025
    What to do if my JIMTEN Plumbing Product motor doesn't work with one of the connected sanitary fixtures?
    • S
      Sara BeanSep 5, 2025
      If the motor isn't working with one of the connected sanitary fixtures, the auxiliary connections might be obstructed, or the non-return valve could be blocked. Try cleaning the auxiliary connection section of pipe. It could also be due to a lack of aeration or gradient in the auxiliary connection; in this case, provide the installation with secondary ventilation or install an aeration valve (Jimten A-69 type). If the problem persists, it may be caused by a malfunction of the microswitch, so reconsider the installation and contact Technical Assistance.
  • M
    Mary SmithSep 8, 2025
    What to do if the JIMTEN Plumbing Product motor starts and stops indiscriminately after draining?
    • L
      logan27Sep 8, 2025
      If the motor starts up and stops indiscriminately after draining, it is likely due to a leak from the non-return valve or loss of water from one of the connected sanitary fixtures. Try cleaning the discharge pipe’s non-return valve and check and replace the joints of the taps of the connected sanitary fixtures.
  • V
    Vicki JamesSep 12, 2025
    Why does my JIMTEN Plumbing Product motor start repeatedly before stopping?
    • N
      nbarnesSep 12, 2025
      If the motor starts up repeatedly before stopping for good, it's likely due to water returning to the lifting station because the non-return valve isn't working properly. Try carrying out a number of discharges with clean water and clean the non-return valve.

Summary

SAFETY INSTRUCTIONS

DETAILED SAFETY INSTRUCTIONS

Comprehensive safety advice and operating instructions for user reference.

SYSTEM SETUP

INSTALLATION RECOMMENDATIONS

Guidelines for piping, bends, frost protection, and connections for optimal setup.

INDICATIONS FOR END USERS

MAINTENANCE OPERATIONS

START-UP AND OPERATION PROBLEMS

Covers issues like unit not starting, motor buzzes, or indiscriminate starting/stopping.

DISCHARGE AND FLOW PROBLEMS

Addresses slow discharge, motor not discharging, or water returning to the basin.

LAYOUT AND SECONDARY VENTILATION SYSTEM DIAGRAM

JIMTEN CICLON LS EB-705 Specifications

General IconGeneral
BrandJIMTEN
ModelCICLON LS EB-705
CategoryPlumbing Product
LanguageEnglish