cod. 3541I710 — Rev. 00 - 06/2016
VENUS BA MS 24 - 34
IT -
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
EN -
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
FR -
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
ES -
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
RU -
ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ, ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ

Questions and Answers

  • M
    mitchell39Sep 23, 2025
    How to fix heating sensor fault in Joannes VENUS BA MS 24- 34 Heater?
    • M
      Michelle SpencerSep 23, 2025
      If your Joannes Heater is showing a 'Heating sensor fault,' the sensor might be damaged. In this case, replace the sensor.
  • A
    Austin BrownAug 23, 2025
    What to do if Joannes Heater shows overtemperature protection intervention?
    • N
      natasha33Aug 23, 2025
      If your Joannes Heater displays an 'Overtemperature protection intervention,' start by checking the heating sensor's position and operation. Next, verify water circulation in the system by inspecting the circulating pump. Finally, vent the system to remove any air.
  • P
    Paige WyattAug 25, 2025
    What to do if Joannes VENUS BA MS 24- 34 has no flame after ignition stage?
    • B
      Bill KerrAug 26, 2025
      To address a 'No flame after ignition stage' issue in your Joannes Heater, check the position of the ionization electrode and replace it if necessary. Also, inspect the burner for any instability. Check the Offset adjustment at minimum power of the gas valve. Clear any obstructions from the flue, fume extraction ducts, air inlet, and terminals. Finally, inspect the trap and clean it if necessary.
  • C
    Christopher SanfordAug 27, 2025
    What to do if Joannes Heater shows exchanger protection intervention?
    • L
      lorihebertAug 27, 2025
      If your Joannes Heater displays 'Exchanger protection intervention', check the circulating pump to ensure system water circulation. Also, vent the system to remove any air.
  • B
    Brandon AllenAug 27, 2025
    What to do if Joannes VENUS BA MS 24- 34 Heater shows fan fault?
    • S
      scainAug 28, 2025
      If your Joannes Heater displays 'Fan fault,' check the 3-pin connector wiring for the 230V power supply. Then, check the 4-pin connector wiring for the tachometric signal. Finally, inspect the fan itself for any damage.
  • K
    Kenneth GraySep 18, 2025
    What to do if heating sensor detached from pipe in Joannes VENUS BA MS 24- 34?
    • N
      Nicholas BridgesSep 18, 2025
      If the 'Heating sensor detached from pipe' on your Joannes Heater, check the correct positioning and operation of the heating sensor.
  • R
    ryanhollandSep 15, 2025
    What to do if Joannes Heater has card parameter fault?
    • A
      Andrea WoodSep 15, 2025
      If your Joannes Heater displays 'Card parameter fault,' check the card parameter and modify it if necessary.
  • H
    higginscarlosSep 16, 2025
    What to do if Joannes Heater has controller fault ABM03D?
    • R
      Richard SaundersSep 17, 2025
      If your Joannes Heater displays 'Controller fault ABM03D,' check the ground connection and replace the controller if necessary.
  • M
    Martin GrantSep 6, 2025
    What to do if Joannes Heater has external probe fault?
    • L
      Laura MaxwellSep 6, 2025
      If your Joannes Heater displays 'External probe fault,' check the wiring or replace the sensor if it's damaged or shorted. If the probe disconnected after activating the sliding temperature, reconnect it or disable the sliding temperature.
  • D
    Danny MorrisSep 3, 2025
    What to do if Joannes Heater displays DHW sensor fault?
    • V
      Valerie MayerSep 3, 2025
      If the Joannes Heater displays 'DHW sensor fault,' check the wiring or replace the sensor.

Summary

1. GENERAL WARNINGS

Boiler Operation Controls

3. INSTALLATION

3.1 General Instructions

General guidelines and requirements for boiler installation.

3.2 Place of installation

Guidelines for selecting a suitable location for boiler installation.

3.3 Plumbing connections

Instructions for connecting the boiler's water and heating circuits.

3.4 Gas connection

Procedure for connecting the gas supply to the boiler.

3.5 Electrical connections

Guidelines for safely connecting the boiler to the electrical supply.

3.6 Fume ducts

Fume Duct Connection Types

Details on connecting fume ducts, including coaxial and separate pipe systems.

4. SERVICE AND MAINTENANCE

4.1 Adjustments

Procedures for adjusting boiler settings and parameters.

Gas conversion

Steps for converting the boiler to use a different type of gas.

Boiler Configuration and Testing

4.2 Startup Procedures

4.3 Maintenance Procedures

4.4 Troubleshooting

Diagnostics and Fault Codes

Explanation of fault codes, diagnostic procedures, and error messages.

List of Faults

Table detailing fault codes, their possible causes, and corrective actions.

5.4 Technical Data Table

ErP Product Fiche (VENUS BA MS 24)

ErP Product Fiche (VENUS BA MS 34)

5.6 Wiring Diagram

Joannes VENUS BA MS 24- 34 Specifications

General IconGeneral
BrandJoannes
ModelVENUS BA MS 24- 34