Mounting of panel:
Use the attached front panel drawing (see page 30) as a reference
to create the cutout. Note drawing is not to scale and should not be
used as a template.
Use a pan head screw (diam. 3 mm) type stainless steel screws
to fasten the panel. You will need four screws (not supplied).
The depth of your cutout should be enough to accommodate the wiring,
terminals, switch dimension, and alarm depth from the back of the
panel. Every boat model/manufacturer will have a different configuration,
thus it will be necessary for the manufacturer/boat owner to determine
the optimal location for the panel.
Wiring:
1. See wiring diagrams on page 31 and 32 for Bilge Alert Sensor
72303 and 72303-001/002 respectively.
2. Make sure to install an inline fuse rated to 1A for 72303 per wiring
diagram on page 31.
3. The wiring connections should be made with water resistant
permanent terminals. Liquid electrical tape should be used to coat
the terminals. The mount connections should be above the highest
water level.
Operation of detector:
1. After installation of the detector is complete, press the “test” button
(top position on momentary switch). If the wiring is correct the alarm
will activate. The alarm should turn off as soon as the switch is no
longer in the “test” position. If the switch is in the “armed” position